ETS 4100S IO-Link
15
Edition: 2020-07-20
HYDAC ELECTRONIC GMBH
Part no.: 670032
E
Lifelong temperature statistics (Index 276):
Temperature statistics from delivery
on, i.e. over the device's entire life cycle
The entire life cycle is split into measuring range segments. The number of segments
depends on the nominal measuring range. The operating times per measuring range
segment are recorded during the entire life cycle.
Resettable temperature statistics (Index 277):
Temperature statistics since reset.
Reset by means of standard command 172
The entire measuring range is split into measuring range segments. The number of
segments depends on the nominal measuring range. The operating times per
measuring range segment are recorded during the entire life cycle, resettable.
Lifelong device temperature (Index 392):
Device temperature values from delivery
on, i.e. over the device's entire life cycle
o
Average value (Subindex 1):
Average device temperature value in °C with 1 decimal place.
o
Minimum value (Subindex 2):
Minimum device temperature value in °C with 1 decimal place.
o
Maximum value (Subindex 3):
Maximum device temperature value in °C with 1 decimal place.
Resettable device temperature (Index 393):
Device temperature
since reset. Reset
using standard command 172.
o
Average value (Subindex 1):
Average device temperature value in °C with 1 decimal place.
o
Minimum value (Subindex 2):
Minimum device temperature value in °C with 1 decimal place.
o
Maximum value (Subindex 3):
Maximum device temperature value in °C with 1 decimal place.
Lifelong device temperature counter (Index 394):
Device temperature counter
from delivery on, i.e. over the device's entire life cycle
o
Number of shortfalls (Subindex 1):
Device temperature value below the lowest nominal measuring range limit.
o
Number of overruns (Subindex 2):
Device temperature value beyond the upper nominal measuring range limit.
o
Number of measuring faults (Subindex 4):
Measuring fault device temperature
Resettable device temperature counter (Index 395):
Device temperature counter
since reset. Reset using standard command 172.
o
Number of shortfalls (Subindex 1):
Device temperature value below the lowest nominal measuring range limit.
o
Number of overruns (Subindex 2):
Device temperature value beyond the upper nominal measuring range limit.
Lifelong device temperature statistics (Index 396):
Device temperature statistics
from delivery on, i.e. over the device's entire life cycle
The entire life cycle is split into measuring range segments. The number of segments
depends on the nominal measuring range. The operating times per measuring range
segment are recorded in s during the whole life cycle and cannot be changed.