19.3 Relevant data for IO-Link
Features
Block Parameters
Yes
Data Storage
Yes
Profile Characteristic
0x0001 (Device Profile: Smart Sensor),
0x8000 (Function Class: Device Identification),
0x8001 (Function Class: Binary Data Channel),
0x8002 (Function Class: Process Data Variables)
Supported Access Locks
Parameters
Data Storage
Local Parameterisation
Local User Interface
Communication
IO-Link revision
V1.1 / support V1.0
Transmission Rate, Baud rate
38.4 kBaud * (COM2)
Minimum cycle time
2.5 ms
Process data width
16 bit
SIO Mode Supported
Yes
M-Sequence Capability
PREOPERATE = TYPE_0 with 1 octet on-request data
OPERATE = TYPE_2_2 with 1 octet on-request data ISDU
supported
* Connection with unscreened standard sensor line possible
up to a max. line length of 20 m.
Download the IO Device Description (IODD) from:
→