Technical data HFT 2500
Input data
Measuring ranges
[l/min]
Size 1
Size 2
Size 3
Size 4
0.005..0.06 0.02 .. 0.2 10 .. 30
0.2 .. 4.0
8 .. 90
0.04 .. 0.13 0.2 .. 0.6
15 .. 45
0.6 .. 5.0
5 .. 110
0.1 .. 0.6 0.4 .. 1.8
20 .. 60
0.5 .. 8.0
10 .. 150
0.2 .. 1.2 0.8 .. 3.2
30 .. 90
1 .. 14
35 .. 220
0.4 .. 2.0 2 .. 7
60 .. 150
1 .. 28
35 .. 250
0.5 .. 3.0 3 .. 13
2 .. 40
1.0 .. 5.0 4 .. 20
4 .. 55
8 .. 30
1 .. 70
Operating pressure
Brass version
Stainless steel version
300 bar
350 bar
300 bar
350 bar
250 bar
300 bar
200 bar
300 bar
Pressure drop [bar]
0.02 .. 0.2
0.02 .. 0.3
0.02 .. 0.4
0.02 .. 0.8
Mechanical connection
see device dimensions / mounting dimensions
Wetted components
Brass version
Stainless steel version
Stainless steel 1.4571; brass nickel-pl.; brass; hard ferrite;
Seal: NBR
1)
Stainless steel 1.4571; hard ferrite; Seal: Viton
1)
Output data
Output signal, max. load
resistance, max. current
4 .. 20 mA, 3 wire, RLmax~ 600
Ω
0 .. 10 V, 3 wire Imax~ 10 mA
Accuracy
≤
± 10 % FS
Repeatability
2 % FS
Environmental Conditions
Operating temperature
range
-20 .. 70 °C
Fluid temperature range
-20 .. 70 °C
mark
2014/30/EU; 2011/65/EU; 2015/863/EU
Protection type acc. to
DIN EN 60529
2)
IP65 / IP67
Other data
Supply voltage
24 V DC (19 .. 30 V DC)
Power consumption
< 1 W
Housing material
Measuring element
Transmitter
Brass (nickel-plated) or stainless steel 1.4571
Aluminum
Electrical connection
Plug connection M12x1
Weight
See device dimensions / mounting dimensions
Notes:
FS
(
F
ull
S
cale) = relative to complete measuring range
1)
Other seal materials on request
2)
With mounted
mating
connector in corresponding protection class