HYCON HPP09L Скачать руководство пользователя страница 7

 

EC-Declaration of Conformity

 

 

 

 
 

 

 
 

 

 
 

 

 

We hereby declare that 
  

HPP09L hydraulic powerpack 

 from serial No. 17227 

(with 6.6 kW petrol engine) 

 

is manufactured in conformity with the EC Directives 2006/42/EC and 2000/14/EC. 
 

 

Notified Body 2914:  
 

Sweco Danmark A/S  

Ørestads Boulevard 41  
2300 København S  

Danmark 

 
Guaranteed sound power level: 101 dB 

 

 
 

HYCON A/S 

Juelstrupparken 11 
DK-9530 Støvring 

Denmark 

 

 

Martin Møller 

Managing Director 
26.07.2019 

 

HYCON A/S 

Juelstrupparken 11 

DK-9530 Støvring 
Denmark 

 

Tel: +45 9647 5200 

Fax: +45 9647 5201 
Mail 

[email protected]

 

www.hycon.dk 

 

Содержание HPP09L

Страница 1: ...ic oil prior to operation To ensure smooth operation and long lasting performance of your new powerpack we recommend you to study this operating manual carefully and pay special attention to the Safet...

Страница 2: ...e Safety precautions 2 Filling up hydraulic oil 2 Technical data 3 Starting instructions 4 Service maintenance and hydraulic settings 4 Oil types 5 EC Declaration of Conformity 6 Warranty Terms 7 Spar...

Страница 3: ...from a vehicle we recommend the use of a crane 8 The pressure relief valve is set at 150 bar from our plant Never set it higher 9 Always use filters with by pass The use of filters without by pass may...

Страница 4: ...Working pressure nominal 120 bar 1750 psi Pressure relief valve setting 150 bar 2200 psi Pump type Gear pump Oil temperature Max 70 C 160 F Hydraulic oil tank capacity Min Max 5 litres 7 litres 1 3 g...

Страница 5: ...ulic oil filter 1 x replacement Check hoses tighten up if needed Air filter 1 x replacement Fuel filter 1 x replacement Use only filters with by pass Hydraulic Settings Check the working pressure by m...

Страница 6: ...r packs use standard hydraulic oil i e all types of mineral oil and biodegradable oil which comply with the following values Ambient temperature range Below 10 C 50 F 10 30 C 50 86 F Above 30 C 86 F R...

Страница 7: ...rectives 2006 42 EC and 2000 14 EC Notified Body 2914 Sweco Danmark A S restads Boulevard 41 2300 K benhavn S Danmark Guaranteed sound power level 101 dB HYCON A S Juelstrupparken 11 DK 9530 St vring...

Страница 8: ...es to faults that can be related to construction and production errors Faults caused by incorrect operation incorrect handling lack of maintenance or the like will not be accepted as warranty The warr...

Отзывы: