HYCON HPP09L Скачать руководство пользователя страница 3

 

Safety Precautions

 

 

1.

 

Always use protective earplugs. The powerpack complies with the EU noise limits, 
but by daily long-lasting operation there is a risk of hearing defects. 

 

2.

 

Always connect hoses before starting. 

 

3.

 

Never add fuel and oil when the engine is running. 

 
4.  In case of non-operation or performance of service, always turn off the engine. 

  

5.

 

Never start the engine without side covers. 

 

6.

 

Operation of the powerpack without tool connected and with lever at 

“ON” may 

cause overheating of the system and damage to the powerpack.  

 

7.

 

When lifting the powerpack from a vehicle, we recommend the use of a crane. 

 

8.

 

The pressure relief valve is set at 150 bar from our plant. Never set it higher. 

 
9.

 

Always use filters with by-pass. The use of filters without by-pass may blow the 

hydraulic hoses and the filter cover. 

 
 

 

Filling Up Hydraulic Oil 

 

To fill up with hydraulic oil, loosen the 

filter cover on top of the powerpack. 

 

 

Remove the filter element (see photo) 

and fill up with oil. When oil is showing 
at the bottom of the filter unit, there is 

enough oil on the powerpack. 

 

 

Insert the filter element again, mount 

the cover and the powerpack is ready 
for use. 

 

Please note: When connecting new extension 

hoses, it is necessary to fill up with extra 2 litres of 

oil. Therefore, always top up the powerpack when 

connecting new extension hoses.  

 

Содержание HPP09L

Страница 1: ...ic oil prior to operation To ensure smooth operation and long lasting performance of your new powerpack we recommend you to study this operating manual carefully and pay special attention to the Safet...

Страница 2: ...e Safety precautions 2 Filling up hydraulic oil 2 Technical data 3 Starting instructions 4 Service maintenance and hydraulic settings 4 Oil types 5 EC Declaration of Conformity 6 Warranty Terms 7 Spar...

Страница 3: ...from a vehicle we recommend the use of a crane 8 The pressure relief valve is set at 150 bar from our plant Never set it higher 9 Always use filters with by pass The use of filters without by pass may...

Страница 4: ...Working pressure nominal 120 bar 1750 psi Pressure relief valve setting 150 bar 2200 psi Pump type Gear pump Oil temperature Max 70 C 160 F Hydraulic oil tank capacity Min Max 5 litres 7 litres 1 3 g...

Страница 5: ...ulic oil filter 1 x replacement Check hoses tighten up if needed Air filter 1 x replacement Fuel filter 1 x replacement Use only filters with by pass Hydraulic Settings Check the working pressure by m...

Страница 6: ...r packs use standard hydraulic oil i e all types of mineral oil and biodegradable oil which comply with the following values Ambient temperature range Below 10 C 50 F 10 30 C 50 86 F Above 30 C 86 F R...

Страница 7: ...rectives 2006 42 EC and 2000 14 EC Notified Body 2914 Sweco Danmark A S restads Boulevard 41 2300 K benhavn S Danmark Guaranteed sound power level 101 dB HYCON A S Juelstrupparken 11 DK 9530 St vring...

Страница 8: ...es to faults that can be related to construction and production errors Faults caused by incorrect operation incorrect handling lack of maintenance or the like will not be accepted as warranty The warr...

Отзывы: