background image

5. CARE AND MAINTAINANCE

• 

Clean with a damp cloth only - do not use abrasives.

• 

The unit is fitted with a resettable thermal cut-out located on the element, 

a reset should only be attempted when the power is off and by a competent 

person. If you get repeated cut-outs this indicates a problem and you should 

consult the manufacturer for advice.

• 

Periodically (at least every 6 months) remove internal lime-scale build up using 

a standard domestic kettle de-scaling compound.  Access to the tank is via the 

lid at the top of the unit.  You may wish to remove the unit from the wall to 

aid access to the unit for de-scaling. We recommend that this is done by a 

competent person.

6.TECHNICAL SPECIFICATION

Model

MBS3

MBS6

MBS8

MBS16

MBS25

Power

2.4 kW

2.4 kW

2.4 kW

2.4 kW

2.4 kW

Initial draw off 

20 

38 

50 

100

156

(Cups)

Recovery rate 

150

150

150

150

150

(Cups/hr)

Voltage

230V ~

230V ~

230V ~

230V ~

230V ~

Frequency

50 Hz

50 Hz

50 Hz

50 Hz

50 Hz

Min working 

0.2 bar

0.2 bar

0.2 bar

0.2 bar

0.2 bar

pressure
Max working 

10 bar

10 bar

10 bar

10 bar

10 bar

pressure
Protection

IPX1

IPX1

IPX1

IPX1

IPX1

Dimensions 

370 x 269 

420 x 312

510 x 312

545 x 364

550 x 414 

(HxWxD)

x 153 mm

x 171 mm

x 171 mm

x 218 mm

x 264 mm

Weight 

(Full)

8.6 KG

14.8 KG

17.2 KG

28.8 KG

37.8 KG

*Based on 167ml cup.

*For stainless steel models add the suffix 'SS' to the product code e.g. MBS3SS.

6

Microboil_Layout 1  07/01/2015  14:00  Page 6

Содержание MBS16

Страница 1: ...Microboil Automatic Boiling Water Unit Available in 3 25 Litre models Instruction Manual Version 3 2 Jan 2015...

Страница 2: ...2 IMPORTANT SAFETY POINTS THIS UNIT DISPENSES NEAR BOILING WATER NEVER LEAVE CHILDREN OR THE INFIRM UNATTENDED NEAR THIS APPLIANCE AS BOILING WATER CAN CAUSE SEVERE INJURY THIS APPLIANCE CAN BE USED B...

Страница 3: ...hed to the back by means of two pins located at the top of the unit and two screws at the base of the unit Remove the screws first then lift cover upwards over the tap stem see right Step 2 Wall Mount...

Страница 4: ...enance such as de scaling Plumbing connections Vent Connect the vent pipe to the vent connection Important The vent pipe should be no longer than 400mm fall continuously and discharge to a safe and vi...

Страница 5: ...ty and then bringing the water to temperature The unit will now switch to normal operation which will prioritise boiling over filling so you will only ever receive near boiling water Powering off and...

Страница 6: ...l to aid access to the unit for de scaling We recommend that this is done by a competent person 6 TECHNICAL SPECIFICATION Model MBS3 MBS6 MBS8 MBS16 MBS25 Power 2 4 kW 2 4 kW 2 4 kW 2 4 kW 2 4 kW Init...

Страница 7: ...cted causing a partial vacuum or positive pressure in the tank Allow sufficient time water should get progressively warmer Reset thermal cut out by pressing button located on element Verify 230V mains...

Страница 8: ...posing of electrical and electronic equipment separately enables its components to be recovered and recycled to obtain significant savings in energy and resources In order to underline the duty to dis...

Отзывы: