6. Troubleshooting
Symptom
Corrective action - Failure on installation
The dryer will not run
Ensure that the breaker supplying the dryer is operational.
If it is, disconnect the power and remove the dryer cover.
Taking suitable precautions to avoid electric shock,
reconnect the power and check for voltage at the terminal
block. Verify that connections are made correctly.
The dryer cycles by itself
Ensure that there is no obstruction on or in front of the IR
or runs constantly
sensor. Clean any dirt or debris off the sensor lens. If
problem persists replace sensor.
The dryer makes a loud
Ensure that the supply voltage is correct as specified on
noise and does not run
the rating plate. If circuit board has been damaged,
for a complete cycle
replace the circuit board and IR sensor module.
The dryer runs but air
Ensure that the supply voltage is correct as specified on
stream is low pressure
the rating plate. The dryer will run weakly if the input
and/or low velocity
voltage is too low.