3
2. Installation
Wall Mounting
The hand dryer must be fixed out of reach of a person taking a bath or shower.
•
Place the supplied template against the wall at the desired height (see mounting
height recommendations) and mark locations of 4 mounting holes and cable entry
at knockout (KO) location.
Note: For 2 or more dryers , dryers should be no closer than 610mm on centre.
•
Remove and retain 2 cover screws and front cover.
•
Drill 4 holes holes at locations A, B,C and D of 8mm diameter x 35mm deep.
•
Using the fixings supplied, attach the dryer to the wall.
Electrical
This appliance must be earthed.
Means for electrical disconnection must be incorporated in the fixed wiring
in accordance with the wiring rules.
•
The power cord should be connected following the colour coding below:
➢
Brown: L
➢
Blue: N
➢
Green / Yellow: E
Hand
Dryer
205mm
287mm
180mm
Jetstream 1600_Layout 1 23/06/2015 14:20 Page 3
Содержание Jetstream JET1600
Страница 10: ......