Electrical connection
The heater should be connected to the fixed wiring of the property via an isolation switch
with a break distance of at least 3mm.
Connection is made as follows:
•
Green/Yellow earth wire to terminal marked or “E”
•
Brown live wire to the terminal marked “L”
•
Blue neutral wire to the terminal marked “N”
The heater must be filled with water. Only then may the appliance be connected
to the electricity supply.
Connection of the heater to the electricity supply must take place in accordance
with electric installation standards and as specified by local laws and regulations.
Avoid danger from damaged power supply cables. In the event of damage, the
heater/cable must be replaced by the manufacturer or an au- thorised agent,
or by an equivalently-qualified person.
Ensure that the addition of this heater will not overload the fuse protection in
your electrical supply.
Internal modifications to the product may cause problems if this work is not
carried out by authorised and qualified technical staff. The warranty only applies
if the product has not been modified in any way. i.e. subject to it being in
unchanged condition.
In order to avoid creating an unsafe situation by inappropriate resetting of the
maximum temperature safety heater, this unit may not be powered via an
external switching heater (a time switch for example) or connected to a circuit,
which is regularly switched on and off.
The product is intended for connection to 220-240V single phase supply only.
The heater should only be connected to a supply that meets the specifications
detailed on the rating label.