6. Trouble Shooting

Fault

Explanation

Solution

The element indicator 

No electrical supply

Check electrical supply

Thermostat set point reached

Turn up thermostat

Too little/no water

Water pressure too low

Check whether other cold 
water taps have the same 
problem

Water flow too low

Open the stop-cock

No water

Turn off the power supply 
and refer to ‘Heater not working’

Signs of leaking

Heater is leaking

Notify the place of purchase

Water connections loose

Tighten/ re seal connections

Tap drips

Water expansion

Nothing, this is normal for 

vented water heaters

Bubbling noise from 

Too much calcification

Arrange for the heater to be 

the tank

de-scaled.

Heater not working

If the heater no longer operates, check whether the fuse or the 
circuit-breaker has tripped. The hot water reservoir is equipped 
with a maximum tempera- ture switch to ensure your safety. 
The heater will automatically switch off if excessive heating 
takes place. When this happens, isolate the power supply to 
the appliance for a few minutes by removing and allow the 
appliance to cool. The appliance can be reconnected to the 
mains power supply again after approximately 20 minutes.

does not light up

10

HF05LM _Layout 1  18/05/2015  10:54  Page 10

Содержание HF05LM

Страница 1: ...Product Instruction Manual Handyflow Oversink HF05LM 5L vented point of use water heater Version 3 2 Jan 2015 v15 4...

Страница 2: ...2...

Страница 3: ...uld be installed by qualified persons All repair and maintenance work on the heater for example the removal of limestone and water scale deposits may only be carried out by duly authorised technical s...

Страница 4: ...8 EC The product also conforms to the following harmonised European standards E 62233 2008 EN 60335 1 2012 EN 60335 2 21 2003 AI 2005 Hyco Manufacturing Ltd Castleford West Yorkshire WF10 5NR 30 04 20...

Страница 5: ...e positioned before attaching the bracket Plumbing Connect the inlet valve to the cold pipe indicated by the blue collar and make the plumbing connection via the 15mm compression fitting supplied Conn...

Страница 6: ...he manufacturer or an au thorised agent or by an equivalently qualified person Ensure that the addition of this heater will not overload the fuse protection in your electrical supply Internal modifica...

Страница 7: ...water volume litres minute 5 Nominal capacity kW 2 Nominal voltage V 1 N PE 230V Frequency Hz 50 Protection class I I IP rating IP24 Water connection inches G1 2 Connector material Brass Dimensions h...

Страница 8: ...shooting for further details Temperature setting Cold heater is switched off Frost protection the device switches on if the water temperature falls below 7 C Heats water to approx 32 C Economy positio...

Страница 9: ...ot require any maintenance by the user Professional maintenance should always be carried out by an expert If faulty never try to repair the heater yourself Please contact the nearest service specialis...

Страница 10: ...Tap drips Water expansion Nothing this is normal for vented water heaters Bubbling noise from Too much calcification Arrange for the heater to be the tank de scaled Heater not working If the heater n...

Страница 11: ...of one year from the date of purchase Hyco will in its sole discretion replace repair or refund any faulty unit Incorrect installation frost damage and the consequences of limescale deposits are exclu...

Страница 12: ...to a dealer providing this service Disposing of electrical and electronic equipment separately enables its components to be recovered and recycled to obtain significant savings in energy and resource...

Отзывы: