COLD WATER INLET

Fig. 6

Fig. 7

Installation instructions

The installation, electrical connection and first 
operation of this heater should be carried out 
by a qualified installer.
The company does not accept liability for 
failure of any goods supplied which have not 
been installed and operated in accordance 
with the manufacturers instructions.
These instructions should be kept for reference 
by the owner of the appliance.

 

If this unit is exposed to static mains 
water pressure, the water container 

may start leaking and cause damage.

Installation and water connections

Make sure that no accessories are left in the 

packing. 

Use mounting template 

in the packing.

Please note the following when installing the 

unit:

  The water heater must be installed vertical-

ly, with the inlet and outlet connections at 

the bottom of the unit  

(Fig. 5 and 6). 

  The inlet tap should be fitted to the right-

hand connection (cold water inlet, Fig. 6).

  The spout should be fitted to the left-hand 

connection (hot water outlet) (Fig. 6).

  Install in a frost-free environment.

  Do not restrict the outlet pipe. Do not  

  connect any aerators or hose with jet 
  control.

 

The spout also acts as a vent.  
Only open-outlet fittings can be 

used with this appliance.  It should NOT be 
used with standard taps.

Installation

An installation template is provided.
Position and fix heater to wall using mounting 
bracket supplied observing water connecions:
  Blue  =  Cold water inlet
  Red  =  Hot water outlet.

 

NOTE -The water connections must 
always remain at the bottom of the 

heater. It cannot be turned upside down.

 

If you confuse the connections, the 
water heater will not function, and 

will cause damage!

 

8021.01

4992.01

24

22

Содержание Handyflow HF05L

Страница 1: ...serviced by approved service technicians in accordance with these instructions Fig 1 HF05L Hyco Handyflow 5L HF10L Hyco Handyflow 10L Point of Use Water Heater Operating and installation instructions...

Страница 2: ...otherwise To avoid risk of accidental resetting of the protective temperature restrictor in the event of a fault the unit must not be con nected via a timer switch If you experience kettling noises o...

Страница 3: ...eight 3 0 kg 5 1 kg Heating power see unit rating plate Voltage 230V Flow rate max 5 l min 10 l min Protection to EN 60529 IP 24 D Connection line approx 700 mm Temperature setting range fully adjust...

Страница 4: ...heater must be installed vertical ly with the inlet and outlet connections at the bottom of the unit Fig 5 and 6 The inlet tap should be fitted to the right hand connection cold water inlet Fig 6 The...

Страница 5: ...ure can reduce the risk of scalding save energy reduce scaling The temperature can be limited to 38 C 45 C 55 C and 65 C Fig 10 key 1 Thermostat control knob 2 Factory set position 85 C 3 Limiting pos...

Страница 6: ...he thermostat sensor and the safety thermal cut out sensor in the HF05L are located in different capillary tubes The thermostat sen sor should be positioned in accordance with Figure 12 HF10L The ther...

Страница 7: ......

Страница 8: ...8 1 8238 HD Subject to errors and technical changes HYCO Manufacturing Ltd Units 1 2 Calder Works Methley Road Castleford West Yorkshire WF10 1NX Tel 0 1 9 7 7 5 1 7 5 5 5 Tel 0 1 9 7 7 5 1 7 6 6 6 Ma...

Отзывы: