Operating instructions

for the user and for the installer

Description

The non-pressure HF05L and HF10L water 
heater keeps 5 or 10 litres of hot water avail-
able for use at any preselected temperature. 
Fig. 2 shows the time that it will take to reheat 
the water should the entire volume be used 
up.

 

• The water heater must not be 
pressurized. Never block the fitting 

outlet and do not use a Perlator or hose 
with jet controller. 

 

• If the temperature is set higher than 
45 °C, very hot water can flow immedi-
ately! 

 

• Keep children and the disabled (physi-
cal/mental) away from this unit unless they 
are supervised by a person responsible for 
their safety or have been given instructions 
on how to use it. 

 

• Ensure that children do not adjust the 
temperature (to a high temperature) on 
the unit when playing -  

Risk of scalding! 

 

• We recommend the use of the tempera-
ture restrictor set by the engineer, unless 
absolutely necessary otherwise. 

 

• To avoid risk of accidental resetting of the 
protective temperature restrictor in the 
event of a fault, the unit must not be con-
nected via a timer switch.

If you experience kettling noises or a reduced 
water flow it is likely that the unit needs 
descaling.

While the system is heating up, water will drip 
from the spout.

To select the temperature 

(Fig. 4)

1

 Control knob

 

 

=  cold. This setting protects

 

your water heater against frost. 
It does not protect your taps 
and pipework.

 

E

 (60 °C) =  Recommended energy-saving 

 

setting. Minimal scale build up.

 

85 °C

  =  Maximum temperature

   

  setting.

2

 Indicator lamp. Illuminates during the heat-

ing-up process.

Fig. 3 shows the amount of warm water 
that you can obtain by mixing cold water (at 
15 °C) to the hot water in the HF05L and 
HF10L.
Example:
with the thermostat control knob set at 
65 °C, the HF05L can supply 10 Litres of
water at 40 °C, when mixed with cold water 
at 15 °C.

Fig. 2

Fig. 4

Fig. 3

40 °C

  45 l 

  40 l

  35 l 

  30 l

  25 l

  20 l

  15 l

  10 l

 

5 l 

 

0

HF10L

HF05L

 

40 °C 

55 °C  E  65 °C 

85 °C

 

40 min

 

35 min   

30 min

 

25 min

 

20 min

 

15 min

 

10 min

 

5 min

 

0

HF05L

HF10L

 

40 °C 

55 °C  E  65 °C 

85 °C

2

1

9183.01

Содержание Handyflow HF05L

Страница 1: ...serviced by approved service technicians in accordance with these instructions Fig 1 HF05L Hyco Handyflow 5L HF10L Hyco Handyflow 10L Point of Use Water Heater Operating and installation instructions...

Страница 2: ...otherwise To avoid risk of accidental resetting of the protective temperature restrictor in the event of a fault the unit must not be con nected via a timer switch If you experience kettling noises o...

Страница 3: ...eight 3 0 kg 5 1 kg Heating power see unit rating plate Voltage 230V Flow rate max 5 l min 10 l min Protection to EN 60529 IP 24 D Connection line approx 700 mm Temperature setting range fully adjust...

Страница 4: ...heater must be installed vertical ly with the inlet and outlet connections at the bottom of the unit Fig 5 and 6 The inlet tap should be fitted to the right hand connection cold water inlet Fig 6 The...

Страница 5: ...ure can reduce the risk of scalding save energy reduce scaling The temperature can be limited to 38 C 45 C 55 C and 65 C Fig 10 key 1 Thermostat control knob 2 Factory set position 85 C 3 Limiting pos...

Страница 6: ...he thermostat sensor and the safety thermal cut out sensor in the HF05L are located in different capillary tubes The thermostat sen sor should be positioned in accordance with Figure 12 HF10L The ther...

Страница 7: ......

Страница 8: ...8 1 8238 HD Subject to errors and technical changes HYCO Manufacturing Ltd Units 1 2 Calder Works Methley Road Castleford West Yorkshire WF10 1NX Tel 0 1 9 7 7 5 1 7 5 5 5 Tel 0 1 9 7 7 5 1 7 6 6 6 Ma...

Отзывы: