background image

3. Operation

3.1        Panel controls

              ON/Off

Time, day and temperature settings

              Mode selection and programs

Increase selected criteria

              Decrease selected criteria

3.2         LCD Display

1. Hour

6. Eco mode

11. Select program

2. Day

7. Frost mode

12. Timer

3. Program number

8. Sleep mode

13. 24 hour display

4. Programmed temperature

9. Radiator lock

14. Time scale

5. Comfort mode

10. Heating on

3.3 Turning on the radiator

1.

Switch power supply on to unit

2.

Turn the radiator on using the switch on the underside of the appliance
where the power cable enters the radiator

3.

Briefly press the on/off button until the on/off icon on the display panel
disappears – you are now in Free Operating Mode.

3.4         Unlocking the radiator

1.

The radiator will automatically lock if left unattended for 30 seconds.

2.

To unlock the radiator at any time (a key icon will be visible in the middle-left
pane of the display) press the up and down arrows at the same time.

3.5         Setting the time and date

1.

In Free Operating Mode, press C/M

2.

The time digits in the top left of the display will start to flash.

3.

Use the up and down arrows to select the desired hour.

4.

Press C/M again to cycle through the minutes and repeat the process.

7

Содержание AVG1500T

Страница 1: ...Product Instruction Manual Avignon AVG600T AVG900T AVG1500T AVG1800T Aluminium radiator Version 3 2 Jan 2015 V18 3 2...

Страница 2: ...king the radiator 3 5 Setting the time and date 3 6 Free operating mode 3 7 Timer Mode 3 8 Programming your radiator 3 9 Program mode 3 10 Default temperature settings 3 11 Daily settings P1 P9 3 12 F...

Страница 3: ...ring Regulations Only connect the unit to a single phase supply with a mains voltage as specified on the rating plate The supply cord cannot be replaced by the user If the cord is damaged the applianc...

Страница 4: ...d and do not modify the bracket In order to avoid overheating do not cover the heater Fixed heaters likely to be used in bathrooms are to be installed so that switches and other controls cannot be tou...

Страница 5: ...lugs and fasten the bracket onto the wall using the screws provided Fig 3 Ensure that the plastic mounting brackets are fitted to the back of the radiator as shown Offer up the radiator to the bottom...

Страница 6: ...age as specified on the rating plate If the heater is to be connected to the fixed wiring of the property then installation must include a double pole isolating switch with a break contact distance of...

Страница 7: ...he appliance where the power cable enters the radiator 3 Briefly press the on off button until the on off icon on the display panel disappears you are now in Free Operating Mode 3 4 Unlocking the radi...

Страница 8: ...clock appears use the up and down arrows to select the amount of time you would like the radiator to stay on for After the display has stopped flashing a clock icon will appear 3 The radiator will swi...

Страница 9: ...our The pre set programs are provided to make things easier for you However these programs are 100 customisable 3 12 Fine tuning P1 P9 1 Select the program you wish to alter as above in Entering Progr...

Страница 10: ...the radiators ON button The symbol FO disappears from the display Activating the Open Window Function 1 Press P Prog once Using the up and down arrows select FO from the list of abbreviations and pre...

Страница 11: ...oft dry cloth Never use chemical or abrasive cleaners Clean the radiator at least once a year with a vacuum cleaner to remove any accumulated dust 5 Specifications Model AVG600T AVG900T AVG1500T AVG18...

Страница 12: ...room temperature control select one At minimum heat output elmin 0 kW single stage heat output and no room temperature control No In standby mode elSB 0 001 kW two or more manual stages no room temper...

Страница 13: ...room temperature control select one At minimum heat output elmin 0 kW single stage heat output and no room temperature control No In standby mode elSB 0 001 kW two or more manual stages no room temper...

Страница 14: ...room temperature control select one At minimum heat output elmin 0 kW single stage heat output and no room temperature control No In standby mode elSB 0 001 kW two or more manual stages no room temper...

Страница 15: ...room temperature control select one At minimum heat output elmin 0 kW single stage heat output and no room temperature control No In standby mode elSB 0 001 kW two or more manual stages no room temper...

Страница 16: ...onic equipment separately enables its components to be recovered and recycled to obtain significant savings in energy and resources In order to underline the duty to dispose of this equipment separate...

Отзывы: