Thank you for purchasing a Hyco Avignon electric radiator. The Avignon 
electric radiator is a stylish, modern fixed heating solution that is ideal for
application in both home and office environments. Available in 4 power 
outputs, this range features a slim line design and uses advanced 
technology to provide comfort and efficiency across a variety of 
applications. Please read and understand these instructions before 
commencing installation, and leave them with the user when installation 
is complete.

1. Important safety points

  

The Electrical installation must be carried out by a qualified electrician in 

              accordance with the current edition of the I.E.E. Wiring Regulations.

             Only connect the unit to a single phase supply with a mains voltage 

              as specified on the rating plate.

             The supply cord cannot be replaced by the user. If the cord is damaged the 

              appliance should be returned to the manufacturer or an authorised service 
              agent for replacement.

             Do not carry the appliance by the power cord.

             Do not let the power cord hang over the appliance.

             The heater must not be located immediately below or above an electrical 

              socket outlet.

             This appliance can be used by children aged from 8 years and above and 

              persons with reduced physical, sensory or mental capabilities or lack of
              experience and knowledge if they have been given supervision or instruction 
              concerning use of the appliance in a safe way and understand the hazards 
              involved.

             Children of less than 3 years should be kept away unless continuously supervised.

3

Содержание AVG1500T

Страница 1: ...Product Instruction Manual Avignon AVG600T AVG900T AVG1500T AVG1800T Aluminium radiator Version 3 2 Jan 2015 V18 3 2...

Страница 2: ...king the radiator 3 5 Setting the time and date 3 6 Free operating mode 3 7 Timer Mode 3 8 Programming your radiator 3 9 Program mode 3 10 Default temperature settings 3 11 Daily settings P1 P9 3 12 F...

Страница 3: ...ring Regulations Only connect the unit to a single phase supply with a mains voltage as specified on the rating plate The supply cord cannot be replaced by the user If the cord is damaged the applianc...

Страница 4: ...d and do not modify the bracket In order to avoid overheating do not cover the heater Fixed heaters likely to be used in bathrooms are to be installed so that switches and other controls cannot be tou...

Страница 5: ...lugs and fasten the bracket onto the wall using the screws provided Fig 3 Ensure that the plastic mounting brackets are fitted to the back of the radiator as shown Offer up the radiator to the bottom...

Страница 6: ...age as specified on the rating plate If the heater is to be connected to the fixed wiring of the property then installation must include a double pole isolating switch with a break contact distance of...

Страница 7: ...he appliance where the power cable enters the radiator 3 Briefly press the on off button until the on off icon on the display panel disappears you are now in Free Operating Mode 3 4 Unlocking the radi...

Страница 8: ...clock appears use the up and down arrows to select the amount of time you would like the radiator to stay on for After the display has stopped flashing a clock icon will appear 3 The radiator will swi...

Страница 9: ...our The pre set programs are provided to make things easier for you However these programs are 100 customisable 3 12 Fine tuning P1 P9 1 Select the program you wish to alter as above in Entering Progr...

Страница 10: ...the radiators ON button The symbol FO disappears from the display Activating the Open Window Function 1 Press P Prog once Using the up and down arrows select FO from the list of abbreviations and pre...

Страница 11: ...oft dry cloth Never use chemical or abrasive cleaners Clean the radiator at least once a year with a vacuum cleaner to remove any accumulated dust 5 Specifications Model AVG600T AVG900T AVG1500T AVG18...

Страница 12: ...room temperature control select one At minimum heat output elmin 0 kW single stage heat output and no room temperature control No In standby mode elSB 0 001 kW two or more manual stages no room temper...

Страница 13: ...room temperature control select one At minimum heat output elmin 0 kW single stage heat output and no room temperature control No In standby mode elSB 0 001 kW two or more manual stages no room temper...

Страница 14: ...room temperature control select one At minimum heat output elmin 0 kW single stage heat output and no room temperature control No In standby mode elSB 0 001 kW two or more manual stages no room temper...

Страница 15: ...room temperature control select one At minimum heat output elmin 0 kW single stage heat output and no room temperature control No In standby mode elSB 0 001 kW two or more manual stages no room temper...

Страница 16: ...onic equipment separately enables its components to be recovered and recycled to obtain significant savings in energy and resources In order to underline the duty to dispose of this equipment separate...

Отзывы: