background image

5. Specifications

AR1000T 

 AR1500T 

A

R

2000T

Supply 

230v~ 50Hz 

Power (half/full) 

500/1000W 

 750/1500W 

 1000/2000W

Water resistance

IP24

Class 

I

Weight

5

.

8

kg 

7

.

5

kg 

9

.

25

kg

  

Thermal protection 

Auto reset thermostat x 2

Size (w x d x h) 

515

x

105

x

675

x

105

835

x

1

0

5

x

4

50

mm

4

50

mm

4

5

0mm

Model Identifiers: Ariano panel heaters AR100T,AR1500T & AR2000T

 Item

Symbol 

Value

Unit

AR1000T 

AR1500T 

AR2000T

 Heat output

 Nominal heat output       Pnom            1.0 

1.5 

2.0

kW

 Minimal heat output        Pmin              0.5 

0.75 

1.0 

kW

 (indicative)

 Maximum continuous     Pmax, c         1.0 

1.5 

2.0 

kW

 heat output

 Auxiliary electricity consumption

 At nominal heat

elmax 

kW

 output 

 At minimum heat              elmin 

kW

 output

 In standby mode               elSB 

0.37 

W

10

Содержание Ariano AR1000T

Страница 1: ...Product Instruction Manual Ariano AR1000T AR1500T AR2000T Glass Panel heater Version 3 2 Jan 2015 V19 2 1 Day Timer MON 08 00 ...

Страница 2: ...portant safety points The electrical installation must be carried out by a qualified electrician in accordance with the current edition of the I E E Wiring Regulations Only connect the unit to a single phase supply with a mains voltage as specified on the rating plate If the heater is located in a bathroom it must be installed so that switches and other controls cannot be touched by a person in th...

Страница 3: ...d in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children aged from 3 years and less than 8 years shall not plug in regulate and clean the appliance or perform user maintenance CAUTION Some parts of this product can become very hot and cause burns Particular attention mu...

Страница 4: ...rface and insert the wall plugs supplied Insert the supplied screws into the wall plugs leaving 5mm of thread protruding Hang the heater to the screws by locating them into the centre of the three corresponding brackets and then sliding the unit to the right and down to secure Specification Model L mm H mm L1 mm L2 mm H1 mm H2 mm AR1000T 515 450 220 110 350 270 AR1500T 675 450 380 190 350 270 AR20...

Страница 5: ...fixed wiring of the property via a double pole fused spur with a break capacity of no less than 13amps Electrical connections should be made as follows Green Yellow earth wire to the terminal marked E or Brown Red live wire to the terminal marked L Blue Black neutral wire to the terminal marked N Circuit diagram 1 5 Heating element KSD thermostat KSD thermostat Temperature sensor Switch Tip over s...

Страница 6: ...ns on the remote control or on the touch screen simultaneously for 2 3 seconds a beep will sound and the current day setting will flash Use the buttons to cycle to the correct day and press the M A button to store The hour indicator of the display will flash use the buttons to cycle to the required value and press the M A button to store The minute indicator of the display will flash use the butto...

Страница 7: ...ck on again at which point it will revert to operating in manual mode It is strongly recommended to consider setting a timed operation using the auto mode where anticipated usage is predictable to avoid energy wastage Auto mode This mode allows the heater to be operated by a user defined schedule This offers up to four separate periods of operation to be defined for each day of the week This featu...

Страница 8: ... If the shut down time runs into the next day you will see the current day on the day indicator automatically cycle to the next day Turn on the display screen by pressing the standby on off button Select Auto mode via the control by pressing the M A button until A is displayed Press the Set button on the remote control and the current day will flash Use the buttons to cycle to the required day and...

Страница 9: ...ed periodically attention should be given to the inlet grilles at the base of the unit and the outlet louvres at the top of the heater Ensure they are cleared of dust or other debris that may causes a blockage and in turn reduce the airflow in and out of the heater which if unchecked may lead to the unit running at hotter temperatures Ensure the heater is isolated from the power supply and has ful...

Страница 10: ...75x105x 835x105x 450mm 450mm 450mm Model Identifiers Ariano panel heaters AR100T AR1500T AR2000T Item Symbol Value Unit AR1000T AR1500T AR2000T Heat output Nominal heat output Pnom 1 0 1 5 2 0 kW Minimal heat output Pmin 0 5 0 75 1 0 kW indicative Maximum continuous Pmax c 1 0 1 5 2 0 kW heat output Auxiliary electricity consumption At nominal heat elmax 0 kW output At minimum heat elmin 0 kW outp...

Страница 11: ...s day timer No electronic room temperature control plus week timer Yes Other control options multiple selections possible room temperature control with presence detection No room temperature control with open window detection Yes with distance control option No with adaptive start control No with working time limitation No with black bulb sensor No 6 Guarantee and service policy This product is co...

Страница 12: ...or to a dealer providing this service Disposing of electrical and electronic equipment separately enables its components to be recovered and recycled to obtain significant savings in energy and resources In order to underline the duty to dispose of this equipment separately the product is marked with a crossed out dustbin Contact us If you experience a problem with this product you should first co...

Отзывы: