3. DMX-512 --7CH mode DMX table
Channel
Value
Function
CH1
0---255
Master dimmer
CH2
0--255
Red dimmer
CH3
0--255
Green dimmer
CH4
0--255
Blue dimmer
CH5
0--255
White dimmer
CH6
0--9
No strobe
10-255
Strobe from fast to slow
CH7
0--5
Motor stop
6-127
Motor orientation running
128-255
Motor auto running speed from slow to fast
CH8
0--9
Control by DMX
10--72
Multi-Color Fade change from slow to fast
73--134
Multi-Color Jump change from slow to fast
135-197
LED Single Color Jump change from slow to fast
198--220
Sound mode 1
221--255
Sound mode 2
3. Fixture Cleaning
The cleaning of internal must be carried out periodically to optimize light output. Cleaning frequency depends on the
environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of
dirt on the fixture’s optics.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.