MAINTENANCE

 
Your K8 LED should need little or no maintenance during its life span other than periodic cleaning 
of the exterior surfaces, when we suggest using a light detergent and water to sponge off any 
dirt deposits. Should you encounter a problem then please contact Hy-Ram Engineering Co. Ltd 
for technical assistance. We suggest the unit be returned to us for any problems that can’t be 
rectified by telephone. Please note there are no user serviceable parts inside and that a competent 
person must carry out any repairs.
 

RECYCLING AND THE ENVIRONMENT

 
Your K8 LED contains various parts that need to be recycled at the end of its life span, please 
contact your original point of purchase for information on correct recycling of this product to help 
protect the environment.
 

TROUBLESHOOTING

 

1. Light doesn’t power up when the on     button is depressed:

 
a) Is the blue status LED next to the On/Off switch blinking when the unit is neither on charge or 
switched on? If not, there is no power in the battery – place the K8 on charge and fully recharge 
the battery.
 
b) Is the battery charged up? Recharge the battery fully so the charging status LED has cycled 
through to flashing green. If there is still no blue LED blinking once the K8 is taken off charge then 
the unit should be returned to point of purchase for investigation.
 
c) Does the status LED function as normal? If the status LED alternates between green and amber 
rapidly when attempting to switch the K8 on this signifies a failure of the main light engine LED(s) 
or a break in one of the cables supplying them. The K8 must be returned to point of purchase for 
investigation.
 

2. Poor run time or no operation at all:

 
a) Has the battery been left completely flat for an extended period of time? Depending on the 
battery chemistry (Sealed Lead Acid or Lithium Ion) employed within the K8, will determine how 
well the unit recovers from being left in a deep discharged state. If the light still doesn’t operate 
after an attempt at fully recharging, or the duration the light runs for before shutting down is 
significantly reduced from the original specification, then the K8 will need to be returned to point 
of purchase to have a new battery fitted.
 

3. No charge indication:

 
a) The K8 status LED should indicate red, amber or green and you should hear a double beep 
when the K8 is placed on charge. If neither happens then check the supply to the docking charge 

Содержание K8 LED

Страница 1: ...upalite K8 LED portable worklight This product design represents the latest technology in LED portable lighting and is designed to be virtually maintenance free and robust enough to deal with the rigors of a harsh work environment PORTABLE WORKLIGHT www hyram com ...

Страница 2: ...d SLA battery as leaving an SLA battery in a discharged state for more than 24 hours has a detrimental effect on its capacity and lifespan CHARGING YOUR K8 LED Your K8 LED is supplied with a bespoke docking charge rack to provide a convenient and secure way to store and charge it This multifunctional rack can be used as a stand alone unit to sit upon a desk bench or can be fixed to a wall or insid...

Страница 3: ...ot to complete a charge To charge from a mains supply you will need the K8 mains adaptor SLK8LED MC which accepts an input of 100 240V AC 50 60HZ 1 5A It comes fitted with a female Cigar lighter style socket allowing the charge rack to be swapped between both vehicle and mains supplies with ease Whether a mains or vehicle supply is used the K8 can be left indefinitely connected keeping it always t...

Страница 4: ...ere it will remain till it finally cuts out Please use the LED status as an indicator only and not an accurate representation of time The idea is that it warns the user through a bleep at each change of the LED status so provisions can be made to finish a task where the light is being relied on and not leave its user in the dark without warning The K8 LED can be set up in two basic modes torch mod...

Страница 5: ...ergency light triggered to come on when the mains power fails Simply switch on your K8 then place it into the charge docking station switch on the power to the docking station from your mains adaptor SLK8LED MC the light will now go out and the coloured status LED will flash the charge status red amber or green with the standby status blue If the mains supply is then interrupted to the charge dock...

Страница 6: ...ss will default from any of the power settings down to 25 the beeper will then sound every 30 seconds and at the same time the main LEDs will blink once This process will continue until the battery voltage falls to a point where the unit will automatically switch off This process will give users adequate time to retreat to an area of safety without being left in the dark The light cannot be switch...

Страница 7: ...on over a hundred units instantly each unit allows the signal to be rebroadcast so infinite distances and areas can be covered In addition as each command is given the LED on the remote will show the status of the K8 LED battery the battery status can also be seen without changing a function by pressing the top two buttons on the remote simultaneously As a button is pressed you will hear a bleep f...

Страница 8: ... battery fully so the charging status LED has cycled through to flashing green If there is still no blue LED blinking once the K8 is taken off charge then the unit should be returned to point of purchase for investigation c Does the status LED function as normal If the status LED alternates between green and amber rapidly when attempting to switch the K8 on this signifies a failure of the main lig...

Страница 9: ... fuse and try again c Check the cigar plug connection is good with the socket it is connected to d Check the docking charge rack terminals haven t been damaged through misuse They should spring back against the front of the charge rack To check remove the K8 from the rack press the blue buttons on the front face then release them the two spring terminals should sit up against the grey front of the...

Страница 10: ...nds 3 SOS SIGNAL Press and hold brightness button for 5 seconds 4 EMERGENCY LIGHT Automatically comes on when a power failure is detected FOCUSING SYSTEM Variable intensity from spot to full flood DURATION BRIGHTNESS LEVEL SUBJECT TO AMBIENT TEMPERATURES 1 SLA 33 Approx 12 hours 2 LITHIUM 1 33 Approx 21 hours 3 LITHIUM 2 33 Approx 39 hours 4 SLA 66 Approx 6 hours 5 LITHIUM 1 66 Approx 10 5 hours 6...

Страница 11: ...D TRP K8 tripod system extends height to 2750mm OPTIONAL EXTRAS WEIGHT K8 SLA 4 1 Kg K8 LITHIUM 1 2 8 Kg K8 LITHIUM 2 3 5 Kg CHARGE RACK ONLY 0 480 Kg MAINS ADAPTOR 0 450 Kg DIMENSIONS WITH HEAD EXTENDED UP L x W x H 205mm x 125mm x 500mm DIMENSIONS WITH HEAD PACKED DOWN L x W x H 288mm x 125mm x 170mm TECHNICAL DATA CONTINUED Note other country plug types available for mains powered optional extr...

Страница 12: ...irectly into the light head when powered up Do not completely submerse the unit in water No user serviceable parts inside Leave servicing to a qualified person The contents of this manual are subject to change without prior notice We take no responsibility for errors or admissions V1H 130611 Patents Pending Hy Ram Engineering Co Ltd Pelham Street Mansfield Nottinghamshire NG18 2EY Tel 01623 422982...

Отзывы: