If

your

receiver

should

need servicing

under

the warranty,

contact

your

Hy-Gain

dealer

for

the

Hy-Gain

Service

Center

nearest

you.

Please contact

the

Service

Center

before

shipping

your

transceiver

to

him.

All

equipment

returned

for

warranty

repair

must

be ac-

companied

by your sales slip or invoice,

or a copy of either.

Units that

have been modified

cannot

be accepted for repair.

Include

all information

requested

by the Service Center.

Then pack

the unit as follows:

Check the unit to see that all parts and screws are in place. Then wrap

it

in heavy

paper or

put

it

in a plastic

bag.

If the original

carton

is not available,

place the unit

in a strong

carton

that

is at least six

inches bigger

in all three

dimensions

than the unit.

Fill the carton

equally

around

the

unit

with

resilient

packing

material

(shredded

paper,

excelsior,

etc.).

Seal it with

gummed

paper tape, tie it with

a strong

cord,

and ship it by prepaid

express, United

Parcel Service,

or insured parcel post to the Hy-Gain

Service Center.

It

is very

important

that

the

shipment

be well-packed

and

fully

insured.

Damage claims

must be settled

between

you and the carrier

and this can delay repair and return

of the unit to you.

Parts can be purchased

from

the

factory

Customer

Service

Depart-

ment.

All

parts

orders

must

be prepaid

or COD.

When ordering,

please supply

the following

information:

1.

model number

of the unit

2.

serial nu mber of the un it

3.

description

of the part

4.

part nu mber.

Hy-Gain Warranty

Service Department

4900 Superior

Avenue

Lincoln,

Nebraska 68505

Attn:

National

Service Manager

Содержание 670B Hy-Range I

Страница 1: ......

Страница 2: ...This transceiver utilizes a highly advanced unique system of frequency synthesization enabling immediate operation on all 23 channels without the need of additional crystals or adjustments Additional features include a jack for con nection of an optional telephone handset The Hy Range I transceiver is designed to operate from 11 5 to 14 5 volts DC To obtain the best results from your transceiver i...

Страница 3: ...PUSHTO TALI MICROPHONE POWER CORDS DC 12V FUSE HOLDER I REMOTE SPEAKER JACK ANTENNA CONNECTOR ...

Страница 4: ...annels in the 27 MHz Citizens Band 0 7 lV for 10 dB S N N ratio 1st IF 11 275 MHz 2nd IF 455 kHz 3 watts maximum about 100 mA on Standby no signal 23 crystal controlled channels on 27 MHz Citizens Band 5 watts 4 watts all harmonic and spurious suppres sion better than Federal Communi cations Commission and Depart ment of Communications DOC requirements yields high average modulation at average voi...

Страница 5: ...s by the F C C General Considerations Before installing the transceiver in a car truck boat etc be sure to choose a location which is convenient to the operating controls and will not interfere with the normal functions of the driver The transceiver may be mounted to the underside of the instrument panel or dashboard of a car truck boat etc by means of the special bracket supplied with your transc...

Страница 6: ...r by means of coaxial cable Either RG 58 u or RG 8 u coaxial cable may be used The cable should be terminated with a PL 259 coaxial connector Screw the PL 259 coaxial connector onto the antenna jack Caution Do not try to transm it without an antenna connected to the trans ceiver External Speaker EXT SP Jack This jack can be used with any 8 ohm earphone or speaker Inserting a 3 5 mm plug into the j...

Страница 7: ...ble To reduce ignition noise install resistor type spark plugs if these are not already installed If non resistance ignition wiring is used install a 10k ohm suppressor resistor at each spark plug tower of the distributor Install a coaxial capacitor at the ignition coil primary as close to the coil primary as possible This capacitor can be purchased from an electronics parts company or an automoti...

Страница 8: ... I Iii h LLJJ rfl or I I GENERATOR 1m i __ HII I TO I ACCESSORIES i i iBALLAST RESISTOR O 1 uF COAXI i S O 6 E SPARK PLUG BREAKER c ru r CC G NNER FENDER WALL SELF TAPPING SCREW and LOCK WASHER typical SELF TAPPING SCREW and LOCK WASHER typical ...

Страница 9: ...imply turn the control fully counterclockwise Channel Selector Continuously rotating switch selects anyone of 23 channels for transmit and receive operation Mic Jack Connect the push to talk microphone or the optional telephone handset Signa I Strength R F Power Meter During reception the built in meter provides a relative indication of signal strength in S units on the upper scale and offers comp...

Страница 10: ... I I i G i l I I ...

Страница 11: ...x inches bigger in all three dimensions than the unit Fill the carton equally around the unit with resilient packing material shredded paper excelsior etc Seal it with gummed paper tape tie it with a strong cord and ship it by prepaid express United Parcel Service or insured parcel post to the Hy Gain Service Center It is very important that the shipment be well packed and fully insured Damage cla...

Страница 12: ...Hy Gain Electronics Corporation shall carry only such warranty as is available from the manufacturer of such goods and are specifically excluded from Hy Gai n warranties This warranty is void if Hy Gain shall inspect equipment and find that it has been modified or improperly installed or used This warranty is expressly in lieu of all other warranties Expressed or implied and all other obligations ...

Страница 13: ... D DE PUERTO RICO ...

Отзывы: