OPERATING PROCEDURES
MP34.9903
12SEP08
AUXILIARY HAND PUMP OPERATION
NEUTRAL
POSITION
DOWN
POSITION
The auxiliary hand pump can be used to lift the room
anytime the pump will not function.
POSITION
UP
AUXILIARY
HAND PUMP
HANDLE
MOTION
OPERATING
HYDRAULIC
SWITCH
The auxiliary hand pump is a two stage pump that
will produce enough pressure to lift the room. When
lift the trailer as well as retract the landing gear. When
operating the auxiliary pump to lift the room, the pump
handle will seem to "snap" as the pump goes to the
second stage. The pumping action will be easier at
first as the second stage starts to create more pressure.
To operate the auxiliary hand pump, move the hydraulic
switch to the desired position. Insert the hand pump
handle into the handle receptacle and move the handle
in an up and down motion.
It is recommended to operate the auxiliary hand
pump occasionally to check it’s operation.
SIDE VIEW
HANDLE
RECEPTACLE
NOTE: The auxiliary hand pump is not needed to
lower the room.
IMPORTANT: DO NOT USE THE HAND PUMP IF THE FLUID
LEVEL IN THE TANK IS LESS THAN ONE HALF FULL.
The hand pump should not lose it’s prime, but if it does,
see MAINTENANCE - PRIMING THE HAND PUMP.
TOP VIEW
U
O
W
D
N
P
HOLD
PUSH AND
CONTROL
PUMP
SWITCH
O
N
W
U
D
P