ONE ROOM EXTENSION SYSTEM
ELECTRICAL CONNECTION DIAGRAM
TOP VIEW OF
SEE GROUNDING
INSTRUCTIONS
PUMP/MANIFOLD
NOTE: LEVELING SYSTEM
MANIFOLD NOT SHOWN
SEE ELECTRICAL
CONNECTION DIAGRAM
ROOM EXTENSION
PUMP RELAY
B
A
BA
6245
5000
5100
6245
ROOM 1 CYLINDER EXTEND
SOLENOID VALVE
ROOM 1 CYLINDER RETRACT
SOLENOID VALVE
VALVE
RELEASE
NUT
VALVE
RELEASE
NUT
ROOM EXTENSION
PUMP/MANIFOLD HARNESS
BOX WITH ROOM EXTENSION
DIAGRAM - CONTROL
ELECTRICAL CONNECTION
SEE
DETAIL A
26
13
25
24
12
11
12
13
13
11
12
11
25
26
26
24
25
24
O-RING
POPPET
CHECK
CAP
SPRING
VALVE
13 - CYLINDER RETRACT
SOLENOID VALVE - 5100
12 - CYLINDER EXTEND
SOLENOID VALVE - 5000
RELAY - 6810
+12 FROM PUMP
+12 ACC - 6120
25 - 7541
26 - 7541
11
24
MP85.304E
08MAY03