MP85.3035
19JAN99
VIEW FROM TOP
MANIFOLD DIAGRAM
+
GROUND
BATTERY
(WHITE)
* FUSE
* FUSE MAY BE REQUIRED - CHECK APPLICABLE CODE
IF THE PUMP BRACKET IS WELDED TO THE
FRAME USE THE GROUND STUD TO ATTACH THE
THE PUMP TO THE BRACKET. IF THE PUMP BRACKET
IS BOLTED TO THE FRAME, USE THE GROUND STUD
TO ATTACH THE BRACKET TO THE FRAME.
-
(GRAY)
PUMP/MANIFOLD
HARNESS
(BLACK)
A
(ORANGE) 3400
(WHITE) 6240
(GREEN) 2400
A
B
B
(BLUE) 1400
B
A
(BROWN) 4400
(BLACK) 8100
A
B
PUMP/MANIFOLD
HARNESS
RR
RF
LF
LR
PRESSURE
SWITCH (50 PSI)
310 SERIES LEVELING SYSTEM
HYDRAULIC MANIFOLD-PUMP RELAY
ELECTRICAL CONNECTION DIAGRAM
SEE GROUNDING
INSTRUCTION DIAGRAM
PACKARD CONNECTORS
COLORS TO A & B ON
DO NOT REVERSE WIRE
(WHITE) 6241
(WHITE) 6240
(WHITE) 6241
NOTE:
FUSE 40 AMP
FUSE
15 AMP
(RED) 6810
EXTENSION
MANIFOLD
HARNESS
ROOM
PUMP RELAY
SEE ELECTRICAL
CONNECTION DIAGRAM
ROOM EXTENSION SYSTEM
6233
NOTE: THE (4) DIGIT WIRE NUMBER
SUPERSEDES ANY AND ALL WIRE
COLORS.
6231
8600
6100
NOTE: THE (4) DIGIT WIRE NUMBER
SUPERSEDES ANY AND ALL WIRE COLORS.
NOTE: PUMP MUST BE MOUNTED SOLIDLY
TO FRAME. SOME PUMPS HAVE A GROUND
CABLE THAT IS TO BE ATTACHED TO THE
GROUND STUD.