background image

Poseidon2 3468 

– Manual 

HW group 

 

 

www.HW-group.com 

16   

 

Specifications 

ETHERNET  

Interface  

RJ45 (100BASE-Tx) 

– 10/100 Mbps network compatible 

Supported protocols 

IP: ARP, TCP/IP (HTTP, NTP, SMTP,

 

netGSM, HWg-PUSH), UDP/IP (SNMP) 

SNMP compatibility 

Ver.1.00 compatible, partial ver.2.0 implementation 

   

Logger  

Internal memory 

250,000 records in flash memory

 

Logged items 

Sensors, DI, DO 

 

SENSORS  

Type 

HWg original accessories: 1-Wire & 1-Wire UNI 

Connector 

2xRJ11 (1-Wire UNI)  

Sensors  

Up to 8 sensors in total (tempe humidity combo sensors count as 2 sensors) 

Sensor distance 

Up to 60m 

   

DI 

– DRY CONTACT INPUTS  

Port 

I1, I2, I3, I4 

Type 

Digital Input (supports NO/NC Dry contact) 

Sensitivity 

1 (On) = 0

–500 Ω   

Max. distance 

Up to 50m 

 

 

OUTPUTS  

Port / type 

OUT1, OUT2 / Relay contacts (NC-COM-NO) 

Max. load 

max. 24V / 16A DC; max. 250V / 16A AC 

State 

Power up state (no state restart memory) 

 

POWER input  

 

Type 

You can power the device from power input 1 or 2. 

Power input 1 

POWER 9-30V DC 

– 2,5W

 

Jack 9

–30V DC (barrel, inner 2.5 mm outer 6.3 mm) + Terminal Block  

Power input 2 

Terminal Block 48V DC 

 

POWER output 

 

Voltage 

Power input 1 (9-30V): Power Out = Power IN (9-30V) 

 

Power input 2 (48V): Power Out = 12V  

Current / Connector 

Max. 150mA  / Terminal Block 

 

LED status indicators 

POWER (RJ45 + top) 

Green 

– power OK (top), Ethernet enabled (RJ45) 

LINK & Activity (RJ45) 

Yellow - Ethernet connectivity 

Setup / Alarm 

Red  

Inputs 

Green 

Outputs 

Yellow 

 

DIP SWITCH 

DIP1: Setup 

OFF   = Normal state

 

Load defaults: 

Set ON,

 

power-up device, toggle 3 times during first 5 seconds  

DIP2: Security 

ON   = Secure mode (online demo) 

– remote configuration disabled

 

OFF = Non-secure mode 

– remote configuration enabled 

   

Physical parameters    

Temperature range 

Operating: -

30 to +75 °C (-22 to 167 °F)  /  Storage: -35 to +85 °C (-31 to +185 °F) 

Dimensions / Mass 

145 x 90 x 45 [mm] / 225 g 

EMC 

FCC Part 15, Class B,  CE - EN 55022, EN 55024, EN 61000 

Содержание Poseidon2 3468

Страница 1: ...Poseidon2 3468 MANUAL...

Страница 2: ...Poseidon2 3468 Manual HW group www HW group com 2...

Страница 3: ...wing conditions The device is noticeably damaged The device does not function properly Unfastened parts can move inside the device The device has been exposed to moisture or rain The device has been s...

Страница 4: ...Poseidon2 3468 Manual HW group www HW group com 4...

Страница 5: ...properly the LINK LED lights up after a short while and then flashes whenever data are transferred activity indication 2 Configuring the IP address UDP Config UDP Config utility root directory of the...

Страница 6: ...name optional Click the Apply Changes button to save the settings Alternatively you may use the following utilities to configure the IP address UDP Config for Linux Important To reset the device to f...

Страница 7: ...iew of current readings General Setup IP address DNS security username password SNMP SNMP SNMP Trap configuration ports and alarm recipients E mail Configuration and test GSM RFID Configuration and te...

Страница 8: ...he device is in the Alarm state For example every 15 minutes NOTE Configuration changes must be confirmed by clicking the Apply Changes button Sends a test e mail and shows the connection log 1 Correc...

Страница 9: ...oseidon2 3468 Manual HW group www HW group com 9 GSM Log Time IP address of HWg SMS GW to use for sending text messages SMS Press to synchronize the time with the specified server Recipients phone no...

Страница 10: ...connected sensors and displays detected sensors Sends an E mail if the Safe Range for this sensor is exceeded To avoid numerous false alerts by e mail or SMS whenever the reading fluctuates around th...

Страница 11: ...inputs Inputs NOTE Configuration changes must be confirmed by clicking the Apply Changes button Poseidon family manual For a detailed description of all settings and tabs see the Poseidon family manu...

Страница 12: ...rolled remotely o On if any alarm The output is active if at least one input or sensor is in alarm o On if value equal to Trigger The output is active if the selected sensor reading is equal to the Ta...

Страница 13: ...Free HWg PDMS version for 3 sensors Paid versions for 8 20 200 unlimited sensors HWg Trigger Windows application for detecting and reacting to events Detects for instance disconnected devices failed...

Страница 14: ...the SensDesk internet service All devices can be managed from a single WWW interface Watch sensor states display your devices in a map compare trends in time and analyze alarm messages SensDesk is a...

Страница 15: ...nual HW group www HW group com 15 Mechanical dimensions Power output Poseidon2 3468 features the PWR OUT terminals for powering connected sensors and detectors Powered by 9 30V PWR OUT 9 30V Powered b...

Страница 16: ...tate Power up state no state restart memory POWER input Type You can power the device from power input 1 or 2 Power input 1 POWER 9 30V DC 2 5W Jack 9 30V DC barrel inner 2 5 mm outer 6 3 mm Terminal...

Страница 17: ...ly isolated from the rest of the device ID range Outputs use ID addresses from 151 to 180 Digital dry contact inputs Digital input terminals may be connected to voltage free contacts or the GND pin Th...

Страница 18: ...rs can take advantage of the HWg SDK Software Development Kit with an ActiveX interface and ready made examples VB Visual Basic 6 0 3xx examples Borland C 1xx examples Microsoft Visual C 2xx examples...

Страница 19: ...firmware over RS 232 Firmware in the HWg format is available at our website or on the supplied CD Restoring factory defaults To restore the factory default configuration including deleting all passwo...

Страница 20: ...Poseidon2 3468 Manual HW group www HW group com 20 Contact HW group s r o Rumunsk 26 122 Praha 2 120 00 Czech republic Tel 420 222 511 918 Fax 420 222 513 833 http www HW group com...

Отзывы: