2

SERIOUS COMMITMENT

All products of our company carry one year limited warranty from the

date of shipment. If any such product proves defective during this warranty

period we will maintain it for free. Meanwhile we implement lifetime service.

Except otherwise agreed by contract.

SAFETY REQUIREMENTS

Please read the following safety precautions carefully to avoid body

injury and prevent the product or other relevant subassembly to damage. In

order to avoid possible danger, this product can only be used within the

prescribed scope.

Only qualified technician can carry out maintenance or repair work.

--To avoid fire and personal injury:

Use Proper Power Cord

Only use the power wire supplied by the product or meet the

specification of this produce.

Connect and Disconnect Correctly

When the test wire is connected to the live terminal, please do not

connect or disconnect the test wire.

Grounding

The product is grounded through the power wire; besides, the ground

pole of the shell must be grounded. To prevent electric shock, the

grounding conductor must be connected to the ground.

Содержание HTJL-V

Страница 1: ...ual You can find the changes in the appendix Sorry for the inconvenience If you have further questions welcome to contact with our service department The input output terminals and the test column may...

Страница 2: ...e In order to avoid possible danger this product can only be used within the prescribed scope Only qualified technician can carry out maintenance or repair work To avoid fire and personal injury Use P...

Страница 3: ...ngs Do Not Operate without Covers Do not operate this product when covers or panels removed Use Proper Fuse Only use the fuse with type and rating specified for the product Avoid Touching Bare Circuit...

Страница 4: ...Security Terms Warning indicates that death or severe personal injury may result if proper precautions are not taken Caution indicates that property damage may result if proper precautions are not tak...

Страница 5: ...5 Contents I General Guide 6 II Function Overview 7 III Device Operation 10 IV Soft Reminders 22...

Страница 6: ...it carefully before use No official notice will be made upon any alternation of this manual 1 1 Applicable Range This device is applicable to the fast and accurate qualitative and quantitative measure...

Страница 7: ...tage circuit breakers has been increasing by about 15 each year In the field of high pressure extra high pressure and ultra high pressure switches SF6 has become the only insulating and arc extinguish...

Страница 8: ...isplay of testing data with dynamic flexuous curve analysis drawing Settable alarm lower limit displayed on the screen and optical alarm Automatic calculation of leaking quantity and leaking rate of t...

Страница 9: ...2 5 Pumping Speed 0 4L min 6 Continuous Working Time 5 hours 7 Dashboard Preheat Start up Time 2 minutes 8 Response Time 5 Seconds 9 Recovery Time 10 Seconds 10 Communication Interface USB 1 1 11 Pow...

Страница 10: ...s in the parameter import interface to alter time in the clock setting interface to choose items in the historical record interface Return Press Return to return to the testing page of the main menu S...

Страница 11: ...election including Enter Test Status Inquire Historic Data and Device Function Setting At the same time the sensor self check and the battery level will also be displayed Enter Test is the default set...

Страница 12: ...arge the battery for 4 hours when the battery level is under 25 Figure 3 3 3 After selecting Enter Test Status touch Enter to enter test status after a beep is heard During the sensor preheating the i...

Страница 13: ...alarm point in the item Warning Density Setting by choosing the up down left or right keys in Alarm Concentration Setting Choose Left and Right keys to choose different items and Up and Down keys for...

Страница 14: ...g will start running See Figure 7 below Figure 7 Item Measured Density shows the real time data of the current test Max Density shows the peak value of the current test Warning Density refers to the a...

Страница 15: ...LED key again to turn off the LED light 3 9 During the process if the Measure key on the handle trigger is touched or the measuring process has lasted for 4 minutes the instrument will buzz and the me...

Страница 16: ...refer to Figure 11 below Figure 11 After setting touch the Confirm key for data saving process The maximum storage capacity is 100 data When the data saving process is finished the instrument will aut...

Страница 17: ...d rate annual leakage annual leakage rate and curve chart etc If Delete is chosen the chosen data will be deleted If Back is chosen the instrument will turn to Function Selection Interface Figure 2 Fi...

Страница 18: ...rument panel and return to the upper interface Please refer to Figure 15 below Figure 15 3 16 Enter Display Settings function and touch Up or Down key to set the brightness of the screen After adjustm...

Страница 19: ...e 16 below Figure 17 3 18 When you enter Instrument calibration function the instrument can be calibrated on site for the drift after it has been put into use for some time To ensure the reliability o...

Страница 20: ...a curve Please refer to Figure 19 below Figure 19 After 10 seconds the calibration will stop and cue works will appear on the interface that the calibration has been completed and the instrument will...

Страница 21: ...Through upper computer software the data in the instrument can be received analyzed and saved on the PC end 3 22 Please charge the instrument when the battery power is lower than required battery leve...

Страница 22: ...4 3 SF6 gas in standard density of 100ppm is required if the user would like to calibrate the instrument Otherwise the accuracy of the instrument might be affected 4 4 If the measuring process is don...