General 

About this manual 

This manual is intended for persons who are responsible for the installation, use and maintenance of 
the Huygens Optics CamStrobe versions CS-2 and CS-3 (hereafter referred to as CS-2/3). For safe and 
proper working with the device it is required that the device is used in compliance with all the safety 
and handling instructions in this manual. In addition, local accident prevention regulations and 
general safety rules for the location of use must be complied with. 

Installation and use should only be done by persons with a sufficient level of knowledge on these 
subjects. Read the operating instructions carefully before attempting any work on or with the 
device. This manual should be kept in the immediate vicinity of the product for future reference.  

In case you have any questions that are not answered in this manual, please contact your local 
distributer or visit the Huygens Optics website at 

www.HuygensOptics.com

 for contact information 

Name plate 

The CamStrobe versions CS-2 and CS-3 can be identified by the name plate located on the back side 
of the unit. The name plate also contains the serial number of the unit. Please note the serial 
number of the unit here for future reference and in the case of communication with Huygens Optics. 

TYPE: 
 
 

SERIAL NUMBER: 

 
Limitation of liability 

The manufacturer assumes no liability for damage and operation faults resulting from: 

 

Failure to use according to these operating instructions 

 

Improper installation by insufficiently-trained staff 

 

Faulty electrical and mechanical connections 

 

Use for other purposes than the intended purpose of this product  

 

Failure to use original replacement and accessory parts 

 

Any technical modifications done to this product without approval of Huygens Optics 

 

Failure to perform maintenance required for this product 

Particular hazards 

 

WARNING:

 This product produces high intensity light flashes in the frequency 

range between 1 and 150 Hz. These flashes can induce epileptic fits, even with 
people who have previously never experienced epileptic fits before. Make sure 
that persons susceptible to epileptic fits are not in the vicinity when using this 
product. In addition, looking directly or even indirectly into the light beam can 
cause temporary loss of vision, especially in dark environments. 
 

 

WARNING:

 Operating the device can make fast-moving parts appear to be 

standing still. This visual illusion can lead to 

serious or even fatal injuries if not 

recognized as such

 by those observing. Please inform everyone in the vicinity 

of this optical effect, to prevent them from accidently reaching into a running 
machine. 

 

Содержание CamStrobe CS-2

Страница 1: ... camera strobe manual V01 1 Installation and operation manual for CamStrobe CS 2 3 Stroboscopic LED flash light module CS 2 CS 3 Please familiarize yourself with the contents of this manual before installation and operation ...

Страница 2: ...hotocopying recording or other electronic or mechanical methods without the prior written permission of the product owner For permission requests please send your request to the address below Huygens Optics Dr Jeroen Vleggaar Prof Poelsstraat 50 1221HT Hilversum Phone 31 0 624449299 Email info huygensoptics com Website www HuygensOptics com Documentation article number HO CS1 2 DOC NL Version Rele...

Страница 3: ...Installation 8 Preparations 8 Mounting the device 9 Device orientation 9 CS 3 only mounting a camera inside the unit 10 Choosing a suitable LED lens type when ordering 11 Connection to the Huygens Optics Camera interface 11 Connection to other interfaces 12 Connection to an external pulse generator 13 Maintenance 13 Troubleshooting 14 Appendices 16 Appendix A dimensional drawings 16 Appendix B ill...

Страница 4: ...f the unit here for future reference and in the case of communication with Huygens Optics TYPE SERIAL NUMBER Limitation of liability The manufacturer assumes no liability for damage and operation faults resulting from Failure to use according to these operating instructions Improper installation by insufficiently trained staff Faulty electrical and mechanical connections Use for other purposes tha...

Страница 5: ... to 80m s or 300km u without motion blur Technical specifications Dimensionsal CS 2 CS 3 L x W x D See appendix A for dimensional drawings 120 x 120 x 57mm 120 x 120 x 120mm Weight 0 8kg 0 9kg Electrical Nominal supply voltage 12V DC max 16V DC Max power consumption at 150Hz 200µS pulse duration 12W 12V 1A External control Pulses 4 24V minimal pulse width 1 µs Frequency 0 150 Hz devices reduce pul...

Страница 6: ...erminals The operating voltage is indicated on the serial plate As accessories only use the equipment certified or supplied by Huygens Optics WARNING Allow for sufficient ventilation of the electrical parts Lack of ventilation may lead to overheating and subsequent damage of the unit Never cover the device with flammable materials such as cloth paper etc since this introduces a fire hazard WARNING...

Страница 7: ...0µs If the trigger pulse duration is longer than 200µs the light flash will be cut off after 200µs This is illustrated in figure 1 Figure 1 Trigger input pulse and the resulting light output pulse In the same reason damage to the LED s the maximum frequency that the device accepts is also limited The maximum device frequency is specified as 150Hz However the physical limitation is set at about 175...

Страница 8: ... of the device Neutrik NC5MD LX Pin number Function 1 12 V 2 0 V 3 Housing GND 4 Pulse opto 5 Pulse opto Figure 3 terminal and connection cable numbering When using a Huygens Optics signal and power distribution unit the second 5 pin XLR connector can be connected directly to one of the strobe outputs of the distribution unit When the 12V power is correctly connected the green LED on the back side...

Страница 9: ... the beam orientation see Appendix D for ordering information Figure 4 Position of mounting holes On the right a photo of the unit placed in a mounting bracket Device orientation There many orientations possible for light exposure However with shiny surfaces direct reflections of the shiny surface so called specular reflections can inhibit accurate inspection situation in Configuration 1 A preferr...

Страница 10: ...e and can be connected externally through the opening on the back side of the CS 3 device Fig 8 5 Close the front of the unit Make sure the power cables of the LEDs are not in any way between stuck or clamped between the housing parts 6 Open the lid on the top of the device by removing the 4 screws with a 2mm Allen key Fig 9 7 Mount the CS 3 with the camera in the inspection position and connect a...

Страница 11: ...th the strobe light is in the on state only 1 400th of the time When using a camera the luminance during the light pulse is actually more important Under these conditions the value is 400x times higher than the value given in the graphs The choice for a specific LED lens type is dependent on the distance from the object and the required surface area and intensity Table 2 gives typical values for a...

Страница 12: ...nterval of the camera This is schematically shown in figure Make sure that the positive slope of the camera s trigger output is within the exposure interval of the camera Otherwise the camera will show a dark or underexposed image Figure 12 Flash timing with respect to the exposure interval shutter open indicated in green Connection to other interfaces The device can also be connected to other cam...

Страница 13: ...ge and current Note It is important to notice that this pulse voltage level on the pulse terminal is defined with respect to the voltage on pulse terminal of the strobe unit not with respect to ground or the power supply minus terminal This is because the connections for the pulses are galvanically isolated from the rest of the device by means of an opto coupler This galvanic separation can be ove...

Страница 14: ...ctions of the pulse input connections the polarity and chek if the pulse level is between 4 and 24V Device flashing but very dimly 1 Power supply voltage too low should be 12 V 2 Internal electronics failure please contact Huygens Optics Device flashing at correct level but not correctly timed 1 Check polarity of the trigger connections 2 Check for ghost pulses on the trigger connection If you hav...

Страница 15: ...troboscope to which this declaration relates is in conformity with the following standards EN55011 EN55022 RE CE EN61000 4 2 ESD EN6100 4 3 RI EN61000 4 6 CI When operated in accordance with the user guide The technical file is available from the manufacturer using the address data above or electronically from www huygensoptics com Signed on behalf of Huygens Optics Place of issue Hilversum the Ne...

Страница 16: ...HUYGENS OPTICS CS 2 3 camera strobe manual V01 16 Appendices Appendix A dimensional drawings ...

Страница 17: ...HUYGENS OPTICS CS 2 3 camera strobe manual V01 17 Appendix B illumination profiles ...

Страница 18: ...ots of Appendix B 200mm illumination distance Lens type Spot size mm Max intensity LUX 50Hz 50us Tight 135 3000 Medium 155 2900 Wide 165 2400 Ultra wide 264 550 400mm illumination distance Lens type Spot size mm Max intensity LUX 50Hz 50us Tight 180 2000 Medium 200 1420 Wide 210 1120 Ultra wide 420 175 600mm illumination distance Lens Type Spot size mm Max intensity LUX 50Hz 50us Tight 215 1150 Me...

Страница 19: ... 6 Camera Interface cable for GigE Matrix Vision camera Order Code HO CIC MV XX 7 Camera Interface cable for GigE IDS camera Order Code HO CIC IDS XX Camera Interfaces are available with 2 to 4 strobe outputs and either external pulse or incremental encoder input for synchronization 8 Camera Interface pulse input with 2 strobe connection outputs Order Code HO CIF2 001 9 Camera Interface pulse inpu...

Отзывы: