41
3.4 ALARM IN
(Path : MAIN MENU / ALARM IN)
This function is to activate alarm upon detection of sensor..
Set the alarm numbers up to 8 numbers. Please refer to Pic.3 Terminal
configuration for alarm input.
Set the priority of 8 alarm inputs and react to the alarm input in accordance
with the priority.
Lower number means higher priority. Operation by the alarm with higher priority
takes precedence over the alarm with lower priority. In case of the alarms with the
same priority, the camera would be operated by the alarm in turns. On operating
by the alarm with higher priority, the alarm with lower priority would be ignored.
Set according to the connected sensor.
"No sensor" connected
"Normally Open"
"Normally Closed"
Set "On" to activate "ALARM", "PRESET" or "DOME ACTION". Operation by
"PRESET" would be just one time, and after that, operation by "DOME ACTION"
would repeat.
Enables setting up a Preset action.
Enables setting up a Dome action.
3.4.1 ALARM IN SETTING
1) Sensor Num :
2) Priority :
3) Input Contact :
ㆍOff :
ㆍN.O :
ㆍN.C :
4) Activate :
ㆍAUX :
ㆍPreset :
ㆍDome Action :
<Notice>
In case there is no sensor connected, please set "OFF", otherwise it might cause
malfunction.
Enables selecting an alarm output method.(Off/1/2) Off is not support alarm
output. 1 is Relay. 2 is Open collector.
Chapter 3. Menu configuration and operating
ALARM IN
----------------------------------
Sensor Num:
1
Priority:
1
Input Contact:
Off
Activate
├ AUX:
Off
├ Preset:
Off
└ Dome Act:
Off
Set
Back
Exit