2.4.3.3 Mount the terminal part on the ceiling.
2.4.3.4 Use the safety wire to prevent the camera from falling.
2.4.3.5 Connect the terminal block
1) Make a hole of 90 ~ 110mm in diameter.
2) Using the mounting bracket as a tem-
plate drill three holes in the ceiling to
mount the bracket.
3) Fasten three screws to fix the terminal
part on the ceiling.
1) Pull the wire on the bottom of the body
part.
2) Hook the wire over the terminal part
as followed picture.
1) Open the cover of the terminal part to connect terminal block.
2) Refer to terminal block diagram for connection.(Pic.6&7)
3) Close the cover of the terminal part and fasten the screw.
<Caution>
<Caution>
Don't block the ventilation hole.
It may cause malfunction.
Be sure to connect power after all installation are completed.
21
[Pic 8] USING SAFETY WIRE
[Pic 9] INSTALLATION TERMINAL PART
3 hasps for safety wire
Safety wire
Fixing screw 4x35
Terminal part
Mount bracket
Anchor 6x30