6.2 d
escripTion
of
The
elecTric
parTs
The main elements of the electric system are:
• Main panel MG45R-14.1-0
• Push buttons panel MG40-14.2A-0
• Panel MG45R-14.3-0
• Safety switch SQ3 for the v belt protection cover
• Main motor M1
• Electromotor M2 for the cooling pump
Indication
Description
Type / code
Specs
EL
Lamp fitting
Light bulb
E27, cod 4201
OP, cod 6214
40W/230V
F1
Fuse holder
Glass fuse
53 45 60-25
53 32 46-25
250V/10A
If=0,25A
F2
Fuse holder
Glass fuse
53 45 60-25
53 34 32-25
250V/10A
If = 0,2A
F3
Fuse holder
Glass fuse
53 45 60-25
53 58 34-25
250V/10A
If = 0,2A
FR
Thermal relay
TSA 10/6 cod.
3670
In=10A;Is=6A; Ir=4,8A
K
Relay
B 6-30-10
400V~/4kW,
Uc=230 V
M1
Electro motor
MA 112M 28-8/4
3~50Hz, 400V, 1.1/1.9 kW, 750/1500 rpm
M2
Electro pump
Type Siemens
W1-07023-GRE
1~ 50Hz; 230V
P=100W
SA1
Reverse switch
CA10 NLLL113 EF
400V~/5,5 kW
Ith=20A
SA2
Dahlander switch
CA10 A444-600E
400V~/5,5 kW
Ith=20A
SBE
Red button with safety
PTZ-4-RT+
KBH3+SEF-01
240V~/6A
SB2
Push button red
DTFO-RT+
KBH3+SEF-01
240V~/6A
SB1
Push button green
DTFO-GN+
KBH3+SEF-01
240V~/6A
SA4
Light switch
6572.500
230V~/3A
SA3
Switch
6585.200
250V/10A
SQ3
Micro switch
XCK P502
240V~/6A
6.3 i
nsTallaTion
condiTions
The connection to the power supply must be in accordance with EN IEC 60204-1.
The machine must be connected to a 3-phase, 50 Hz, 400V power source with earthing (PE). The power circuit has to
be protected against short circuits and overcurrent.
The electrical system should have insulation value IP 44.
The working conditions for the electric system must comply with the following conditions:
• Max. height above sea level: 2000 m
• Max. ambient temperature -5° to + 40° C
• Relative humidity: 40% to 80% at 25° C