![Hussmann VRM1B Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/hussmann/vrm1b/vrm1b_installation-and-operation-manual_2189914029.webp)
P/N 3034041_D
29
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
VRM Merchandisers
ADJUSTING DOOR SAG
To adjust door sag (saw-tooth effect from door
to door), loosen the two hinge plate mounting
screws using a Torx Plus no. 27 bit. Adjust
hinge plate as needed, then tighten the screws.
CONDITIONING GASKETS
The manufacturer cannot control the
environment surrounding cases during shipment.
Temperature and humidity fluctuations during
shipment, as well as excessive vibration, may
promote gaps between gasket and frame. These
gaps prevent gaskets from sealing even when
correctly fitted at the factory.
This is not a warranty issue or defect.
Follow this procedure to ensure gaps close and
gaskets seal properly:
1. Remove all shipping retainers and all packing
material.
2. Close each door. Use a flashlight to identify
any gaps between frame and gasket.
3. Energize all anti-sweat, fan and light circuits
for at least two hours, but not more than four
hours, prior to initiating the refrigeration cycle.
4. Monitor all gaps. If gaps remain at the end of
four hours, follow the procedure for Restoring
Gasket Seal, beginning on page 6 of this
manual.
5. Initiate cooling sequence once gaps disappear.
Do not exceed 8 hours of energized circuits
without refrigeration. Doing so may cause
damage to the case and will void the warranty.
Before and After Gasket Conditioning
Gap Closed
Gap
ATTENTION
TO ENSURE PROPER DOOR GASKET SEAL - REMOVE ALL SHIPPING
RETAINERS AND ENERGIZE ALL ANTI-SWEAT, FAN & LIGHT CIRCUITS
2 TO 4 HOURS PRIOR TO INITIATING REFRIGERATION CYCLE.
DO NOT EXCEED 8 HOURS OF ENERGIZED CIRCUITS
WITHOUT REFRIGERATION. DAMAGE OR PRODUCT FAILURE MAY
OCCUR AND VOID THE WARRANTY.
DO NOT REMOVE THIS LABEL UNTIL REFRIGERATION IS INITIATED.
Adjusting Door Sag
Loosen both
hinge plate
mounting
screws.