VRM Merchandisers
PLUG
The plug cord is 9 ft long and is located on
the right hand rear of the merchandiser.
Disconnect power before servicing. VRM
merchandisers require a dedicated electrical
circuit with ground. 12AWG is the minimum
sized acceptable wire.
• The VRM models require a dedicated
15 AMP/115V circuit with a grounded wall
receptacle (NEMA 5-15R).
• Always use a dedicated circuit with the
amperage stated on the unit.
• Plug into an outlet designed for the plug.
• Do not overload the circuit.
• Do not use long or thin extension cords.
Never use adapters.
• If in doubt, call an electrician.
VRL-1
VRL-2
VRMB
5-15P
P
6
P
5- P
— LOCK OUT / TAG OUT —
To avoid serious injury or death from electrical
shock, always disconnect the electrical power
at the main disconnect when servicing or
replacing any electrical component. This
includes, but is not limited to, such items as
doors, lights, fans, heaters, and thermostats.
ALWAYS CHECK THE SERIAL PLATE FOR
COMPONENT AMPERES
Risk of Electric Shock. If cord or plug
becomes damaged, replace only with a
cord and plug of the same type.
Merchandiser must be grounded.
Do not remove the power supply cord ground.
ELECTRICAL / REFRIGERATION
All Models
Nominal
Voltage
Minimum
Voltage
Maximum
Voltage
120
108
132