![Hussmann VR3-HV-M Series Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/hussmann/vr3-hv-m-series/vr3-hv-m-series_user-manual_2189369021.webp)
HIGH VOLUME MEAT/FISH SERVICE - SELF SERVICE
REVISION DATE
01/24/18
HUSSMANN - VR3HV-M/F-EP SH, +2H, & +4H OPTIONS (CHINO)
REFRIGERATION DATA:
GPM
PSI
GPM
PSI
GPM
PSI
NSF 7
AHRI 1200
NSF 7
AHRI 1200
4'
1.8
0.7
1.5
0.4
0.3
0.2
0.0
4',6',8',10',12'
230/450
230/450
26/26
26/26
6'
2.6
1.0
3.7
0.5
1.4
0.2
0.2
REAR STORAGE
110
90
20
26
8'
3.5
1.3
1.7
0.7
0.4
0.3
0.5
4',6',8',10',12'
250/450
250/450
20/26*
20/26*
10'
4.1
1.6
2.9
1.0
1.5
0.4
0.7
REAR STORAGE
125
90
20
26
12'
5.2
1.9
3.5
1.0
1.4
0.4
0.9
*EPR REQUIRED FOR FRONT SECTION WHEN SHELF IS USED
**FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB
***REFRIGERATION NOTES:
1) BTU'S DO NOT INCLUDE LIGHTS
2) ADD 10 BTU'S PER FOOT/PER SHELF FOR OPTIONAL LED SHELF LIGHTS
3) 2H OPTION; ADD 45 BTU/HR/FT FOR THE FRONT, ADD 5 BTU/HR/FT FOR THE REAR STORAGE.
4) 4H OPTION; ADD 80 BTU/HR/FT FOR THE FRONT, ADD 10 BTU/HR/FT FOR THE REAR STORAGE.
5) SUBTRACT 75 BTU/HR/FT FROM TOP SECTION FOR ICE PAN APPLICATIONS (NON-SHELF ONLY)
6) THE PRINCIPAL COOLING EFFECT IN FISH CASES IS ACCOMPLISHED WITH A TRADITIONAL ICE BED. THE REFRIGERATION
PRESERVES THE ICE AND MAINTAINS A COLD PROTECTIVE LAYER OVER THE PRODUCT.
7) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY
8) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN P/T TABLES
FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE
DISCHARGE AIR TEMPERATURE SHOWN.
9) RATING CONDITION IS NSF TYPE I, 75°F/55% RH
10) SHELF CASE GRAV COIL SUPERHEAT TYPICALLY 2°F, ALSO INCREASE DEFROST SCHEDULE ~1-2 MINUTES PER 1°F AMBIENT BELOW 75°F
REFRIGERATION DATA CONTINUED:
TOP GRAV
33
32
N/A
TOP DECK
28
27
N/A
FRONT
28
26
N/A
REAR STORAGE
36
37
N/A
1
1.125
WITH SHELF = S
2
1.125
S / TOP GRAV
26
24
N/A
S / TOP DECK
33
32
N/A
S / FRONT
28
26
N/A
S / REAR STOR
36
37
N/A
ELECTRICAL DATA:
STANDARD FANS, HEATERS, LED LIGHTS (115 VOLT)
4'
3
6.70
15
0.4
24
0.3
31
0.1
10
0.4
41
0.9
100
1
115
15
6'
6
6.70
15
0.7
48
0.4
46
0.1
15
0.5
61
1.3
150
1
115
15
8'
6
6.70
15
0.7
48
0.5
62
0.2
21
0.7
82
1.7
200
1
115
15
10'
6
6.70
15
0.7
48
0.6
73
0.2
26
0.9
99
2.2
250
1
115
15
12'
9
6.70
15
1.1
72
0.8
93
0.3
31
1.1
124
2.6
300
2
115
30
OPTIONAL HIGH OUTPUT LED LIGHTS (115 VOLT)
AMPS WATTS
AMPS
WATTS
AMPS
WATTS
4'
0.3
33
0.2
26
0.5
59
1
6.70
30
0.3
8.8
6'
N/A
N/A
N/A
N/A
N/A
N/A
1
6.70
30
0.3
8.8
8'
0.6
66
0.4
51
1.0
117
1
6.70
30
0.3
8.8
10'
N/A
N/A
N/A
N/A
N/A
N/A
1
6.70
30
0.3
8.8
12'
0.9
100
0.7
77
1.5
176
1
6.70
30
0.3
8.8
CASE
LENGTH
NSF 7
NSF 7
DISCHARGE
AIR
TOP/FRONT **
EVAPORATOR
TOP/FRONT
RATING CONDITION
CAPACITY
TOP/FRONT***
(BTU/HR/FT)
VELOCITY
TOP/FRONT
(FT/MIN)
OFF TIME
30
4
45
33~35
380~600
50~100/150~200
4'
6'
8'
MEAT/FISH
33~36/33~36 50~100/150~200
EVAPORATOR FANS:
TOP AND FRONT
CANOPY
LIGHTS LED
TOP AND
FRONT
CASE LENGTHS
CASE USAGE
TEMPERATURE (ºF)
MEAT/FISH
ELEC. THERMOSTAT / AIR
SENSOR SETTINGS
CASE LENGTH
# OF
EVAP
FANS
BLADE
DIA.
(IN.)
USAGE
CUT IN
(ºF)
CUT OUT
(ºF)
M/F w/SHELF
24~29/30~32
AMPS
CONVENIENCE
OUTLETS (OPTIONAL)
AMPS
WATTS
AMPS
WATTS
WATTS
OPTIONAL LED
SHELF LIGHTS
TOP AND FRONT
MAX. LED LOAD
(W/ ALL
OPTIONS)
ANTI-SWEAT
HEATERS
EVAPORATOR FANS:
REFRIGERATED REAR STORAGE
(OPTIONAL)
AMPS
WATTS
BLADE
PITCH (°)
OFF TIME
45
4
43
1.0
N/A
48
2.6
45
0.2
AMPS
BLADE
PITCH
FRONT (°)
AMPS
WATTS
AMPS
WATTS
CASE LENGTH
CANOPY LIGHTS
H.O. LED TOP
AND FRONT
OPTIONAL SHELF
TOP AND FRONT
MAX. H.O. LED
LOAD
12'
10'
BLADE
DIA. (IN.)
# OF
EVAP
FANS
CASE LENGTH
FRONT
TOP
REAR
STORAGE
20°F GLYCOL
6° RISE
#
OUTLETS
VOLTS
END PANEL WIDTH KEY
# OF
END
PNLS
END PNL
WIDTH
(IN.)
TOTAL ADDED
LENGTH (IN.)
EST.
REFG.
CHRG.
404A
(LBS)
1.125
2.25
M/F w/SHELF
33~35
380~600
48
2.4
45
0.2
N/A
DEFROST
TYPE
TIME
(MIN)
DEFROST
FREQUENCY
(#/DAY)
TERM. TEMP
(°F) COIL
ONLY
DRIP
TIME
DEFROST
WATER
(LBS/DAY/FT)
0.6
1 1/8"
96"
1 1/8"
15"
6"
14 1/4"
FRONT OF CASE
17"
12 1/ 2"
53"
56"
17 3/8"
50 3/8"
Upper
Drain
Elect
Drop
Drain
Lower
Refrig
Drop
FRONT
CLO SE-OFF
REAR
CLOSE-OFF
3 7/8"
7"
SUPPORT
LE GS
INSERTI ON
POINT
21
Содержание VR3-HV-M Series
Страница 4: ...Case Sections 4...
Страница 19: ...19 Piping schematic for Serpentine Coil and Gravity Coil Refrigeration cont d...