background image

P/N 3018126_E 

4-1

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483  U.S.A.

SMG8B & SSG8B

3-10

 

s

tartup

 / o

pEratIon

P/N 3018126_E 

U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com

P/N 3018126_E 

4-1

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483  U.S.A.

SMG8B & SSG8B

CARE AND CLEANING  

Long life and satisfactory performance of 
any equipment is dependent upon the care it 
receives. To ensure long life, proper sanitation 
and minimum maintenance costs, these  
merchandisers should be thoroughly cleaned, 
all debris removed and the interiors washed 
down, weekly. 

Exterior Surfaces

The exterior surfaces must be cleaned with a 
mild detergent and warm water to protect and 
maintain their attractive finish. 

n

ever

 

use

 

AbrAsive

 

cleAnsers

 

or

 

scouring

 

pAds

.

Interior Surfaces

The interior surfaces may be cleaned with most 
domestic detergents, ammonia based cleaners 
and sanitizing solutions with no harm to the 
surface. Self contained models empty into a 
limited capacity evaporation pan, which will 
overflow if excess water is used in cleaning.

Do NOT Use:

•Abrasive cleansers and scouring pads, as these 
will mar the finish.

•Coarse paper towels on coated glass.

•Ammonia-based cleaners on acrylic parts.

•Solvent, oil or acidic based cleaners on any  
interior surfaces.

•Do not use high pressure water hoses.

Do:

•Remove the product and all loose debris to 
avoid clogging the waste outlet.

•Store product in a refrigerated area such as a  
cooler. Remove only as much product as can 
be taken to the cooler in a timely manner.

•Disconnect electrical power before cleaning.

•Thoroughly clean all surfaces with soap and 
hot water. 

d

o

 

not

 

use

 

steAm

 

or

 

high

 

wAter

  

pressure

 

hoses

 

to

 

wAsh

 

the

 

interior

.

 

t

hese

 

will

 

destroy

 

the

 

merchandisers

’ 

sealing

 

causing

 

leaks

 

and

 

poor

 

performance

.

•Take care to minimize direct contact between 
fan motors and cleaning or rinse water.
•Do NOT flood merchandiser with water. 

n

ever

 

introduce

 

wAter

 

fAster

 

thAn

 

the

 

wAste

 

outlet

 

cAn

 

remove

 

it

.  

stAndArd

 

cAses

 

Are

 

equipped

 

with

 

A

 

floor

 

drAin

An

 

optionAl

 

drAin

 

kit

 

is

 

AvAilAble

•Allow merchandisers to dry before resuming 
operation.

•After cleaning is completed, turn on power to 
the merchandiser.

MAINTENANCE

Product will be degraded and may spoil if 

allowed to sit in a non-refrigerated area.

Do NOT allow cleaning agent or 

cloth to contact food product.

Содержание SSG8B

Страница 1: ...SMG8B SSG8B Medium Temperature Self Contained Installation Operation Manual P N 3018126_E AUGUST 2018 IMPORTANT Keep in store for future reference MANUAL I O SMG8B SSG8B Diamond tread bumper shown...

Страница 2: ...ORTANT KEEP IN STORE FOR FUTURE REFERENCE Quality that sets industry standards 12999 St Charles Rock Road Bridgeton MO 63044 2483 U S Canada 1 800 922 1919 Mexico 1 800 890 2900 www hussmann com 2018...

Страница 3: ...Operation 3 1 Controller Parameters 3 3 Dixell Control Sensor Location 3 6 Controls and Adjustments 3 7 TEV Adjustment 3 8 Self Contained Location 3 8 Load Limits 3 9 Stocking 3 9 MAINTENANCE Care an...

Страница 4: ...ANSI Z535 5 DEFINITIONS DANGER Indicate s a hazardous situation which if not avoided will result in death or serious injury WARNING Indicate s a hazardous situation which if not avoided could result...

Страница 5: ...he cor rect parts SHIPPING DAMAGE All equipment should be thoroughly examined for shipping damage before and during unloading This equipment has been carefully inspected at our factory Any claim for l...

Страница 6: ...ance and may damage the refrig eration system Do NOT remove shipping crate until the merchandiser is positioned for installation Maintain minimum 4 inch air clearance at rear of case Air Intake Air Ex...

Страница 7: ...eavy objects on the merchandiser SHIPPING SKID Each merchandiser is shipped on a skid to protect the merchandiser s base and to make positioning the case easier Unscrew the case from the skid The fixt...

Страница 8: ...traight upward to clear lower brackets and then down to remove The panel is installed by reversing the above procedure Ensure all panels are installed to prevent air circulation problems The case is s...

Страница 9: ...re it can be re positioned as follows A Remove the glass and clamp hardware from the merchandiser by opening the glass and loosening set screws in hinge Metric 3 millimeter set screws B Slide the glas...

Страница 10: ...ent After all glass has been adjusted as defined in Step 4 the flexible portion of one gasket at a joint may be trimmed with a razor knife Be sure that the remaining wiper gasket seals the gap Verify...

Страница 11: ...of the door frame These must be removed 7 Remove stainless steel top liner by grabbing the rear flange and pulling back Note It is possible to access the adjusting bolt by using a small swivel socket...

Страница 12: ...the adjusting bolt clockwise will raise the front glass Turning the adjusting bolt counter clockwise will lower the front glass Once the glass position is set tighten the set screw positive stop 10 O...

Страница 13: ...SMG8B SSG8B OPTIONAL DISPLAY PAN WIRE RACK AND DIVIDER KIT The wire shelf with divider fits in the case The divider slides from one end to the other sepa rating meat and seafood products Wire Shelf D...

Страница 14: ...extension cord 6 Ensure that the proper electrical requirements for the equipment are supplied 7 Verify field electrical connections are tight 8 Verify all electrical wiring is secured and clear of a...

Страница 15: ...dedicated circuit with the amperage stated on the unit Plug into an outlet designed for the plug Do not overload the circuit Do not use long or thin extension cords Never use adapters If in doubt cal...

Страница 16: ...e Refrigerant must be recovered before attempting any connection or repair Product will be degraded and may spoil if allowed to sit in a non refrigerated area LOCK OUT TAG OUT To avoid serious injury...

Страница 17: ...to browse the parameter codes in programming mode or to decrease the cur rently displayed temperature value Table 4 1 XR75CX Front Panel Keys and Functions onF oFF Switches the light ON and OFF if oA...

Страница 18: ...Alarms P1 Discharge temperature probe failure P2 Defrost termination probe failure HA Max temperature alarm LA Min temperature alarm How to set defrost start time Defrost occurs 24 hours after startup...

Страница 19: ...lows decimal point display dE dE dE Lod Device display P1 P2 P3 P4 SEt dtr Selects which probe is displayed by the device P1 Thermostat probe P2 Evaporator probe P3 Third probe only for models with th...

Страница 20: ...N 10 0 0 FSt Fans stop temperature 50 to 50 C 122 F Setting of temperature detected by the evaporator probe above which fans are always OFF 2 2 2 Fon Fan ON time 0 to 15 min With Fnc C_n or C_y fan ac...

Страница 21: ...cP2 do not select it dEF2 do not select it HES night blind Lig Alr Alr AOP Alarm relay polarity Set if the alarm relay is open or closed when an alarm happens CL terminals 1 4 closed during an alarm...

Страница 22: ...exico 1 800 890 2900 www hussmann com Safe NET Location on Rear of Case Rear Panel Removed Dixell Control Sensor Location Sensor is located under the gravity coil for SMG8B Sensor is located under the...

Страница 23: ...models defrost is time initiated and temperature terminated START UP Follow the Dixell XR75 start up procedures as detailed on Page 3 1 of this manual Each self contained merchandiser has its own eva...

Страница 24: ...ence between the two tem peratures is 3 F to 5 F Make adjustments of no more than 1 2 turn of the valve stem at a time and wait for at least 15 minutes before rechecking the probe tem perature and mak...

Страница 25: ...rchandiser 24 hours to operate before loading product Proper rotation of product during stocking is necessary to prevent product loss Always bring the oldest product to the top and set the newest to t...

Страница 26: ...3 10 Startup Operation P N 3018126_E U S Canada 1 800 922 1919 Mexico 1 800 890 2900 www hussmann com NOTES...

Страница 27: ...ar the finish Coarse paper towels on coated glass Ammonia based cleaners on acrylic parts Solvent oil or acidic based cleaners on any interior surfaces Do not use high pressure water hoses Do Remove t...

Страница 28: ...d be cleaned every six months Dirty louvers will cause mer chandisers to perform poorly The louvers may be cleaned with a vacuum cleaner Soap and water may be used if all water is removed from the lou...

Страница 29: ...CLEANING COILS Condenser coils should be cleaned at least once per month Additional cleaning may be needed depending on the operational environ ment A dirty condenser blocks normal airflow through th...

Страница 30: ...educe the pan s capacity This may cause the drain pan waste water to overflow and spill onto the floor Remove accumulated debris from the drain pan A garden hose can be hooked up to the drain pan to d...

Страница 31: ...at and air registers fans and doors etc x Check for water leaks x Clean evaporator coil s and fan blade s Do not use an acid base cleaner Rinse off any cleaner residue x Clean discharge air honeycombs...

Страница 32: ...4 6 Maintenance P N 3018126_E U S Canada 1 800 922 1919 Mexico 1 800 890 2900 www hussmann com NOTES...

Страница 33: ...n motor and blade 7 Lower fan plenum 8 Reconnect fan to wiring harness 9 Turn on power 10 Verify that motor is working and blade is turning in the correct direction 11 Close air gaps under fan plenum...

Страница 34: ...l will lubricate the rod and seals Failure to lubricate will severely shorten cylinder life Removing a Cylinder Cylinders are a wear item They are designed to support the glass when fully open to allo...

Страница 35: ...mly held in place by the glass clamps Set Screw Locations Apply a drop of Loctite 242 or equivalent threading locking fluid onto each set screw of the glass clamp assembly Tighten all screws with a TO...

Страница 36: ...tight fit HINGE HARDWARE Type Two cylinders and one fastening point P N 0401884 Used on 8 ft and 12 ft 2438 mm and 3658 mm parent cases and as a joining bracket Type Two cylinders and three fastening...

Страница 37: ...information or other support contact your Hussmann representative Please include the model and serial number of the product Hussmann Corporation Corporate Headquarters Bridgeton Missouri U S A 63044 2...

Страница 38: ...Hussmann Corporation 12999 St Charles Rock Road Bridgeton MO 63044 2483 www hussmann com...

Отзывы: