SGN141S-1 R290 Self-Contained Low Height Open Refrigerated Display Cabinet
Manual
Ju
ly
2021 Final Rev: 30A01
8
(1) Tests for cabinet fitted with night cover are as per
AS1731
. Test is with night cover (blind) discarded
(up) and lights on for entire 24-hour test. 2
nd
Test is with night cover (blind) applied (down) for 12 hours
while lights are turned off and 12 hours night blinds up and lights on within the 24-hour test.
(2) Appropriate adjustments to the refrigeration setting parameters may be required to suit actual store
conditions if they vary from Climate Class 3.
SGN141S-1
DRINK CHILLER CASE
Refrigeration Settings [
AS1731
per Climate Class 3 (+25°C/60%RH)]
Basic
Case temperature control options
Product Temperature Class
3M1
(2)
Cabinet control regulation is per
evaporator coil inlet mounted sensor.
Cut-Out / Cut-In (regulation band), °C
0.0 / +6.0
Refrigerant
/ Expansion device
R290/Capillary
Defrost
– #/day x minutes (failsafe)
8 x 25
Superheat, K
~ 5
Refrigeration Rating (Φ
24-def
per
AS1731
, Test 1, Climate Class 3)
Cabinet model (size, mm length overall incl.
ends at 40mm each)
SGN141S-1 (650)
Φ
24-def
– single cabinet system, Watts
(For condensing unit selection purpose)
781
R290 Refrigerant Charge, grams
142
Electrical Data (220V AC 50Hz)
Evap. Fan
Qty x Wattage
– Case air flow
1 x 25
Total Fan Load, Amps
0.12
Lights
LED
Qty x Wattage - Canopy
1 x 7
Qty x Wattage - Shelves
2 x 5
Total amps (LED Adapter) max.
0.09
Unit
Condensing unit (Model)
Embraco EMX6210U
Rated Load, Amp
2.4
Heater
Wattage
– Pan heater
Nil (passive)
Total Heaters, amps
-
Cabinet
Total load, amps.
2.6
Cabinet Energy Consumption & Efficiency Data (
AS1731
, Product Class 3M1)
Test
(1)
Case Size
Cabinet
Type
DEC
kWh/d
REC
kWh/d
TEC
kWh/d
TDA, m
2
TEC/TDA kWh/d/m
2
1
st
Test
SGN141S-1
IVC1
7.680
N/A
7.680
0.553
13.886
GEMS EEI registered values (
AS1731
, Product class 3M1)
MEPS
Reg.
No.
Case Size
Cabinet
Type
DEC
kWh/d
REC
kWh/d
TEC
kWh/d
TDA, m
2
TEC/TDA kWh/d/m
2
ARC0709
SGN141S-1
IVC1
7.680
N/A
7.680
0.553
13.886
Class 3M1