Hussmann SGN141S-1 Скачать руководство пользователя страница 15

SGN141S-1 R290 Self-Contained Low Height Open Refrigerated Display Cabinet

 

Manual

 

Ju

ly

2021 Final Rev: 30A01  

 15

 

Regular Inspection 

To ensure reliability of the cabinet and leak tightness of the refrigerant circuit, it is advisable that 
trained personnel carry out periodic maintenance.

 

Case should be cleaned and inspected by store staff on a daily basis.

 

If an alarm system is not part of the refrigeration installation, the temperature of each case
should be checked on a daily basis.

The case discharge air temperature should be within the following ranges of -4°C ~ +1°C,
unless on defrost.

o

If it is consistently outside the above temperature ranges, contact your service
provider.

Visually check the case for damage or spills and take appropriate remedial action.

Cleaning

 

Do not use hot water on cold glass surfaces as the glass may shatter and cause serious

injury.

When flushing the waste drain, do not use high-pressure water hoses and be careful not

to introduce water faster than the waste outlet/drain can drain it. This SGN141S-1 cabinet

does not have a floor drain. Do not bucket more than 1 litres into the case during cleaning.

CAUTION: - 

Do not climb in or on the cabinet as 

this may result in personal injury and/or case 
damage.

 

1. Remove stock from the case and store below +5°C.

2. Turn off power to the case (electrical).

3. Remove all price tickets and any foreign materials from the case. Particularly the air return

grille / base liner / and defrost tray.

4. Remove shelves and clean with a sponge, warm water and mild detergent, then rinse and

wipe dry.

5. Remove the base trays, wash with mild soapy water and rinse.

6. Carefully flush the waste drain with a small amount of water (less than 2 litres) and allow

the base to drain. NOTE: - monitor the condensate tray levels in the lower section of the
cabinet.

7. Clean the drain area with a soft brush and warm water.

8. Clean the inside of the case (paying particular attention to the perforations in the rear

panels) with a clean soft cloth, warm water and mild detergent.

9. Clean glass or mirrored surfaces with a clean soft cloth and mild glass cleaner.

10. Wipe LED lamps with a dry cloth (ensure lights are powered off).

Содержание SGN141S-1

Страница 1: ...1 The following models are covered by this Manual SGN141S 1 66 Glendenning Road Glendenning NSW 2761 PO Box 42 Doonside NSW 2767 t 61 2 8805 0400 f 61 2 9675 2897 SGN141S 1 Self Contained R290 Low Hei...

Страница 2: ...int 7 Technical Data Sheet 8 Operating Environment 9 Installed Position 9 Key Operation Points 10 Installation _____________________________ Electrical installation 11 12 Cabinet Operation Start up 12...

Страница 3: ...following instructions Each and every operator as well as the maintenance personnel must carefully read und fully understand or have these instructions explained before using this equipment Warning Th...

Страница 4: ...vacuum In such a case i the substitution cannot be performed indoors at the customer s premises ii the cabinet should be moved to a controlled workshop environment suitable for the type of repair wher...

Страница 5: ...td Email warranty_aus hussmann com Phone 61 2 805 0400 New Zealand McAlpine Hussmann Ltd Email taurangasales hussmann com Phone 64 7 578 0965 Prior to installation Cabinets must be stored protected fr...

Страница 6: ...from debris as this could otherwise result in a roller wheel coming to an abrupt stop and destabilise the cabinet 4 Once cabinet is in the required position screw all four 4 feet bolts down into posi...

Страница 7: ...d Low Height Open Refrigerated Display Cabinet Manual July2021 Final Rev 30A01 7 Cross Sections Footprints Load Limits and Data Sheets SGN141S 1 Medium Temperature Self Contained R290 Low Height Open...

Страница 8: ...e R290 Capillary Defrost day x minutes failsafe 8 x 25 Superheat K 5 Refrigeration Rating 24 def per AS1731 Test 1 Climate Class 3 Cabinet model size mm length overall incl ends at 40mm each SGN141S 1...

Страница 9: ...Shopping trolleys Forklift trucks Pallet jacks Floor polishers CAUTION Any of the above situations could prevent the cabinet s from performing correctly Extra consideration may be required to minimize...

Страница 10: ...substantial energy reduction This cabinet appliance cannot be used by children or people who are not properly trained The refrigerant charge is factory set and should not be tampered with Warranty may...

Страница 11: ...installation shall Meet existing regulations and safety codes Have an electrical supply to the cabinet that is independent of other supplies and have its own dedicated fixed power supply socket Exten...

Страница 12: ...e cabinets have a load limit that ensures food products stored within these load limits are p roperly refrigerated Food products stored outside these load limits may not be properly refrigerated and d...

Страница 13: ...cleaning Check drain trap is clear of obstructions Do not flood the base of the cabinet or well area as water may overflow the small volume water tray in the bottom section of the cabinet onto the flo...

Страница 14: ...gate Use warm water to de ice coil if required but not so much as to flood the well condensate tray in the lower section of the cabinet Use a soft brush or vacuum brush to clean coil Use PPE gloves sa...

Страница 15: ...than the waste outlet drain can drain it This SGN141S 1 cabinet does not have a floor drain Do not bucket more than 1 litres into the case during cleaning CAUTION Do not climb in or on the cabinet as...

Страница 16: ...emove by pulling this panel forward Refer to photo sequence inserted further below NOTE no tools are required to remove or replace the condenser air filter panel or filter 2 Use appropriate PPE 3 Make...

Страница 17: ...SGN141S 1 R290 Self Contained Low Height Open Refrigerated Display Cabinet Manual July2021 Final Rev 30A01 17 b c Condenser Filter Media Mesh Condenser Filter Media Mesh removed and fully cleaned...

Страница 18: ...Low Height Open Refrigerated Display Cabinet Manual July2021 Final Rev 30A01 18 d e Cleaned condenser filter media mesh placed back into the condenser air filter panel Fix front panel on its location...

Страница 19: ...lean carefully avoid touching other components Put the air filter and front grill panel back in place 2 Ensure the air filter once cleaned is replaced in the same position adjacent to the air on face...

Страница 20: ...onnected to a floor drain 10 Clean the waste drain trap with a soft brush and warm water 11 Wipe down the inside of the case including the perforated rear air delivery panels and air return grill with...

Страница 21: ...be undertaken by store staff Please contact your service provider for all maintenance queries Trouble shooting issue possible reason remedial action Product temperature is higher than requirement Stor...

Страница 22: ...d compared to design climate class 3 Check store air conditioning operation If store condition cannot be lifted then adjust cabinet set points and defrost strategy to suit Cabinet exterior is sweating...

Страница 23: ...t service provider The compressor doesn t start after 2 minutes The power supply cable is disconnected Reconnect plug The circuit breaker has tripped Contact service provider The unit is damaged Conta...

Страница 24: ...aning electrical fittings and components Electrically isolate cases before work is carried out Staff training RCD Keep electrical connections dry at all times Falling Climbing on shelves Staff must be...

Страница 25: ...ork begins An electrical work must be carried out by an appropriately trained service provider To obtain warranty information or other support contact your nearest Hussmann representative Please inclu...

Страница 26: ...ts retainer position 9 The shelves should be in the correct positions but if not these can be re positioned in the normal manner after the transport retainer clip located above each shelf and on each...

Страница 27: ...e the case electrically Removal of the case is to be in the reverse order of installation listed previously Case disposal is to be carried out by the following Metal component removed and recycled rem...

Страница 28: ...SGN141S 1 R290 Self Contained Low Height Open Refrigerated Display Cabinet Manual July2021 Final Rev 30A01 28 Appendix A Wiring Diagram...

Отзывы: