Wiring Color Code
Standard CaseWireColorCode
CASE MUST BE GROUNDED
NOTE: Refer to label affixed to case to determine the
actual configuration as checked in the “TYPE
INSTALLED” boxes.
Electrical Circuit Identification
Standard lighting for all models will be full length fluorescent
lamps located within the case at the top. The switch
controlling the lights, the plug provided for digital scale, and
the thermometer are located at the rear of the case mullion.
The receptacle that is provided on the exterior back of these
models is intended for computerized scales with a five amp
maximum load, not for large motors or other high wattage
appliances. It should be wired to a dedicated circuit.
Electrical Service Receptacles (When Applicable)
The
receptacles located on the exterior of the merchandiser are
intended for scales and lighted displays. They are not
intended nor suitable for large motors or other external
appliances.
Color Decsription
Color
Ground
Green
Anti-Sweat
Purple
Lights
Orange
Receptacles
Yellow
T-Stat/Solenoid 230VAC
Red/Black
T-Stat/Solenoid 115VAC
White/Black
T-Stat/Solenoid 24VAC
Red/White
Fan Motors
Brown
Blue Condensing Unit
Use Copper Conductors Only
430-01-0338 R101003
DANGER
BEFORE SERVICING
ALWAYS DISCONNECT ELECTRICAL
POWER AT THE MAIN DISCONNECT
WHEN SERVICING OR REPLACING ANY
ELECTRICAL COMPONENT.
This includes (but not limited to) Fans, Heaters
Thermostats, and Lights.
2-2
P/N 3068445 _
B
Field Wiring and Serial Plate
Amperage
Field
Wiring
must
be
sized
for
component
amperes
printed
on
the
serial
plate.
Actual
ampere
draw
may
be
less
than
specified.
Field
wiring
from
the
refrigeration
control
panel
to
the
merchandisers
is
required
for
refrigeration
thermostats.
Case
amperes
are
listed
on
the
wiring
diagram,
but
always
check
the
serial
plate.
LED Driver
Location
Drivers are located within the access panel that runs the
length of the rear of the case. Refer to diagram on page
4.
Ashrae
Color
Code
NOTE:
All
other
manufacturers
have
no
standard
sensor
codes.
Waste Outlet and P-TRAP
The
waste
outlet
is
located
off
the
center
of
the
case
on
one
side
allowing
drip
piping
to
be
run
lengthwise
under
the
fixture.
A
1-1/2"
P-TRAP
and
threaded
adapter
are
supplied
with
each
fixture.
The
P-TRAP
must
be
installed
to
prevent
air
leakage
and
insect
entrance
into
the
fixture.
NOTE:
PVC-DWV solvent cement is recommended.
For
installation or maintenance of the P-TRAP use
only adhesive compatible with ABS fittings.
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 •
Item # 18s279
Содержание Q3SSM12R
Страница 10: ...NOTES 1 6 P N 3068445 _B U S Canada1 800 922 1919 Mexico1 800 890 2900 www hussmann com...
Страница 20: ...NOTES 4 6 P N 3068445 _B U S Canada1 800 922 1919 Mexico1 800 890 2900 www hussmann com...
Страница 26: ...Electrical Wiring Diagrams A 3 P N 3068445 _B U S Canada1 800 922 1919 Mexico1 800 890 2900 www hussmann com...
Страница 28: ...Electrical Wiring Diagrams A 5 P N 3068445 _B U S Canada1 800 922 1919 Mexico1 800 890 2900 www hussmann com...
Страница 34: ...Hussmann Corporation 12999 St Charles Rock Road Bridgeton MO 63044 2483 www hussmann com...