background image

4 of 9

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P2XRO-E

Technical Data Sheet

Impact  

Excel 

P2XRO-E

All Produce

Electrical Data

4 ft

6 ft

8 ft

12 ft

Number of Fans—7W

1

2

3

Number of Fans—4W

2

Amperes

Watts

4 ft

6 ft

8 ft

12 ft

4 ft

6 ft

8 ft

12 ft

Evaporator Fan

120V

60Hz

Standard

0.50

0.62

1.00

1.50

39

48

78

117

120V

50Hz

Standard

0.55

0.76

1.10

1.65

42

54

84

126

230V

60Hz

Export

0.25

0.30

0.50

0.75

39

48

78

117

230V

50Hz

Export

0.28

0.36

0.56

0.84

42

54

84

126

120V

60Hz

Energy Efficient

0.19

0.24

0.38

0.57

14

16

28

42

230V

60Hz

Energy Efficient

0.10

0.12

0.20

0.30

14

16

28

42

Minimum Circuit Ampacity

120V

60Hz

Standard

0.70

0.82

1.20

1.70

120V

50Hz

Standard

0.75

0.96

1.30

1.85

230V

60Hz

Export

0.45

0.50

0.70

0.95

230V

50Hz

Export

0.48

0.56

0.76

1.04

120V

60Hz

Energy Efficient

0.39

0.44

0.58

0.77

230V

60Hz

Energy Efficient

0.30

0.32

0.40

0.50

Maximum Over Current Protection 120V

20

20

20

20

Maximum Over Current Protection 230V

15

15

15

15

Standard Lighting (T-8 fluorescent)

1 Row Canopy

0.26

0.51

0.51

0.77

30

59

59

85

Optional Lighting (T-8 fluorescent)

Additional 1 Row Canopy

0.26

0.51

0.51

0.77

30

59

59

85

Additional 2 Row Canopy

0.51

1.02

1.02

1.54

59

118

118

170

Additional 3 Row Canopy

0.77

1.53

1.53

2.31

89

177

177

255

1 Row Rail Light

0.26

0.51

0.51

0.77

30

59

59

85

Optional Shelf Lighting (T-8 fluorescent)

1 Row of Shelves

0.26

0.51

0.51

0.77

30

59

59

85

2 Rows of Shelves

0.51

1.02

1.02

1.54

59

118

118

170

3 Rows of Shelves

0.76

1.53

1.53

2.31

89

177

177

255

Optional Always*Bright LED Lighting

1 Row of Shelves

0.15

0.19

0.26

0.38

18

23

31

45

2 Rows of Shelves

0.26

0.34

0.47

0.67

31

41

56

80

3 Rows of Shelves

0.38

0.53

0.74

1.11

45

63

89

133

120V Lighting Circuit Total = Standard Li Total Optional Li Optional Shelf Lighting

230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52

Содержание P2XRO-E

Страница 1: ...andard Fan Assembly 1 0392457 Fan Motor Evaporator MO 4410101 0382383 Fan Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 0382383 Fan Blade FB 4780617 Item Part Description Wiring Item B 0411744 Standard Non adjustable 2 Defrost Thermostat CT 0411744 C Optional Adjustable Refrigeration Thermostat 3 LAMPS BALLASTS LED FIXTURES AND POWER SUPPLY D Ballast E...

Страница 2: ...50 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection point B RH End of case to center of stub up area 36 1 4 921 60 1 4 1530 84 1 4 2140 132 3 8 3363 Back of case to center of stub up area 38 1 2 978 38 1 2 978 38 1 2 978 38 1 2 978 ...

Страница 3: ...hr ft per shelf row for fluorescent lamps DEFROST DATA P2XRO E Frequency hr 8 Defrost Water lb ft day 6 15 based on case configuration and product loading OFFTIME P2XRO E Temp Term F 48 F Failsafe Minutes 30 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONAL CONTROLS Low Pressure Backup Control P2XRO E CI CO 17 7 F Indoor Unit Only Pressure ...

Страница 4: ... 60Hz Energy Efficient 0 30 0 32 0 40 0 50 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting T 8 fluorescent Additional 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Additional 2 Row Canopy 0 51 1 02 1 02 1 54 59 118 118 170 Additional 3 Row Canopy 0 77 1 ...

Страница 5: ...l Display Area 3 Sq Ft Ft 3 92 ft2 ft 1 19 m2 m Shelf Area 4 Sq Ft Ft 6 59 ft2 ft 2 01 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated Volume less shelving and other unusable space Refrigerated Volume Unit of Length ft3 ft m3 m 3 Computed using ARI 1200 standard methodology Total Display Area ft2 m2 Unit of Length ft m 4 Shelf s...

Страница 6: ...al Two Row Canopy Optional Three Row Canopy Connector 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy 5 4 5 5 Connector W B BL BL R BL R R R B 4 ft 6 ft or 8 ft 12 ft 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser mu...

Страница 7: ...L FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Two Rows of Shelves 4 ft case Connector 5 4 5 B W Connector 6 ft or 8 ft case 12 ft case R R W BL BL R B BL BL R 5 4 5 B W R R W BL BL R B BL BL R Optional Shelf Lighting Fluorescent Fixtures ...

Страница 8: ...L 7 7 R BL R BL R BL 7 7 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and LED Light Circuits for Two Rows of Shelves R R B Optional Shelf Lighting LED Fixture...

Страница 9: ...BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND W Connector Optional Shelf Harness and LED Light Circuits for 3...