2 of 9

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P2XRO-E

Technical Data Sheet

Engineering

Plan Views

NOTE: Case-to-Case Electrical Connections 
are made IN FRONT OF SPLASHGUARD. 

3

/

(120)

Splashguard

A

41 

1

/

(1054)

3 In. 

(77 mm)

 

Required 

Air Gap

Refrigeration 

Outlet

Electrical 

Stub Up Area 

6 x 6 

(152x152)

 

Waste Outlet

Waste Outlet

FRONT

8

 

(203)

1

/

(115)

12 

1

/

(307)

43 

7

/

(1114)

C

Wireway

3

/

(120)

26 

1

/

(673)

1

/

(108)

Electrical 
Field 
Connection

46 

1

/

(1174)

48

 

(1220)

40 

5

/

(1032)

56 

1

/

(1435)

44 

5

/

(1133)

B

D

41 

1

/

(1054)

38 

1

/

(978)

Produce

10-2005

P2XRO

4 ft

6 ft

8 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

48 

3

/

8

(1229)

72 

3

/

8

(1838)

96 

3

/

8

(2448)

144 

1

/

2

(3670)

(Each end and insulated partition adds 1 

1

/

in. (38 mm) to case line up.)

Maximum O/S dimension of case back to front 

(includes bumper)

56 

1

/

(1435)

56 

1

/

(1435)

56 

1

/

(1435)

56 

1

/

(1435)

Back of case to front of splashguard

48 (1220)

48 (1220)

48 (1220)

48 (1220)

Back of case to O/S edge of front leg

44 

5

/

(1133)

44 

5

/

(1133)

44 

5

/

(1133)

44 

5

/

(1133)

Distance between edges of external legs and center legs

NA

29 

1

/

(750)

41 

1

/

(1054)

41 

1

/

(1054)

Distance between edges of center legs

NA

NA

NA

43 

7

/

(1114)

Distance between front legs and splashguard

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

Electrical Service             

(Electrical Field Wiring connection point)

(B)

RH End of case to center of stub up area

36 

1

/

(921)

60 

1

/

(1530)

84 

1

/

(2140)

132 

3

/

(3363)

Back of case to center of stub up area

38 

1

/

(978)

38 

1

/

(978)

38 

1

/

(978)

38 

1

/

(978)

Length of electrical wireway

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

(C)

RH End of case to LH end of wireway

42 

1

/

(1070)

66 

1

/

(1680)

90 

1

/

(2289)

138 

1

/

(3511)

Waste Outlets  

(One each end)

(D)

RH End of case to the center of LH waste outlet

36 

1

/

(921)

60 

1

/

(1530)

84 

1

/

(2140)

132 

3

/

(3363)

RH End of case to the center of RH waste outlet

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

Back O/S of case to center of waste outlets

46 

1

/

(1174)

46 

1

/

(1174)

46 

1

/

(1174)

46 

1

/

(1174)

Schedule 40 PVC drip pipe

1

/

(32)

1

/

(32)

1

/

(32)

1

/

(32)

Refrigeration Outlet

Back of case to center of refrigeration outlet

40 

5

/

(1032)

40 

5

/

(1032)

40 

5

/

(1032)

40 

5

/

(1032)

RH end of case to center of refrigeration outlet

8  (203)

8  (203)

8  (203)

8  (203)

Dimensions shown as inches and (mm).

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

4

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

7

/

8

Wireway

Содержание P2XRO-E

Страница 1: ...andard Fan Assembly 1 0392457 Fan Motor Evaporator MO 4410101 0382383 Fan Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 0382383 Fan Blade FB 4780617 Item Part Description Wiring Item B 0411744 Standard Non adjustable 2 Defrost Thermostat CT 0411744 C Optional Adjustable Refrigeration Thermostat 3 LAMPS BALLASTS LED FIXTURES AND POWER SUPPLY D Ballast E...

Страница 2: ...50 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection point B RH End of case to center of stub up area 36 1 4 921 60 1 4 1530 84 1 4 2140 132 3 8 3363 Back of case to center of stub up area 38 1 2 978 38 1 2 978 38 1 2 978 38 1 2 978 ...

Страница 3: ...hr ft per shelf row for fluorescent lamps DEFROST DATA P2XRO E Frequency hr 8 Defrost Water lb ft day 6 15 based on case configuration and product loading OFFTIME P2XRO E Temp Term F 48 F Failsafe Minutes 30 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONAL CONTROLS Low Pressure Backup Control P2XRO E CI CO 17 7 F Indoor Unit Only Pressure ...

Страница 4: ... 60Hz Energy Efficient 0 30 0 32 0 40 0 50 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting T 8 fluorescent Additional 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Additional 2 Row Canopy 0 51 1 02 1 02 1 54 59 118 118 170 Additional 3 Row Canopy 0 77 1 ...

Страница 5: ...l Display Area 3 Sq Ft Ft 3 92 ft2 ft 1 19 m2 m Shelf Area 4 Sq Ft Ft 6 59 ft2 ft 2 01 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated Volume less shelving and other unusable space Refrigerated Volume Unit of Length ft3 ft m3 m 3 Computed using ARI 1200 standard methodology Total Display Area ft2 m2 Unit of Length ft m 4 Shelf s...

Страница 6: ...al Two Row Canopy Optional Three Row Canopy Connector 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy 5 4 5 5 Connector W B BL BL R BL R R R B 4 ft 6 ft or 8 ft 12 ft 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser mu...

Страница 7: ...L FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Two Rows of Shelves 4 ft case Connector 5 4 5 B W Connector 6 ft or 8 ft case 12 ft case R R W BL BL R B BL BL R 5 4 5 B W R R W BL BL R B BL BL R Optional Shelf Lighting Fluorescent Fixtures ...

Страница 8: ...L 7 7 R BL R BL R BL 7 7 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and LED Light Circuits for Two Rows of Shelves R R B Optional Shelf Lighting LED Fixture...

Страница 9: ...BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND W Connector Optional Shelf Harness and LED Light Circuits for 3...

Отзывы: