background image

MWG 

Data Sheet

4 of 4

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Impact  

MWG

Meat / Delicatessen

Electrical Data

6 ft

8 ft

12 ft

Number of Fans –9W

1

2  

3  

Amperes

Watts

Merchandiser

6 ft

8 ft

12 ft

6 ft

8 ft

12 ft

Fans

Standard (120V 60Hz)

0.77

1.54

2.31

62

124

186

Export (230V 50Hz)

0.47

0.94

1.41

70

140

210

Energy Efficient (120V 60Hz)

0.38

0.76

1.14

25

50

75

Constant on Anti-sweat Heaters

NA

Cycling Anti-sweat Heaters

NA

Minimum Circuit Ampacity

With Standard Fans (120V 60Hz)

0.97

1.74

2.51

Export (230V 50Hz)

0.67

1.14

1.61

With Energy Efficient Fans (120V 60Hz)

0.58

0.96

1.34

Maximum Over Current Protection (120V)

20

20

20

Maximum Over Current Protection (230V)

15

15

15

Supplemental Gas Heaters

NA

208V 1

Φ

Φ

Electric Defrost 

NA

Standard Lighting

Optional Lighting

Optional Shelf Lighting

None

None

None

Refrigeration

Thermostat

2

To
Condensing
Unit

}

Light Blue

=  120V P

OWER

=  120V N

EUTRAL

WARNING

All components must have mechanical ground, and the merchandiser must be grounded.