background image

3 of 4

P/N 0395228B

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Impact  

MWG

REFRIGERATION DATA

Note:

This data is based on store 

temperature and humidity that does not
exceed 75°F and 55% R.H.

MWG

Discharge Air °F

26

Evaporator °F

18

Unit Sizing °F

16

Btu/hr/ft**

MWG

Parallel

778

Conventional

890

**For all refrigeration equipment other
than Hussmann, use conventional BTU
values.

DEFROST DATA

Frequency (hr)

6

E

LECTRIC OR

G

AS

Not Recommended

Defrost Water (lb/ft/day)

2.2

O

FFTIME

MWG

Temp Term °F

43

°F

Failsafe Minutes

60

CONVENTIONALCONTROLS

Low Pressure Backup Control

MWG

CI/CO**

12°F / 2°F

Indoor Unit Only, Pressure Defrost
Termination**

43°F

**Use a Temperature Pressure Chart to
determine PSIG converisons.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

2

Liquid Line (in.)

3

/

8

Suction Line (in.)

7

/

8

Estimated Charge (lbs)***

MWG

6 ft

2.3

8 ft

2.8

12 ft

4.3

***This is an average for all refrigerant
types actual refrigerant charge may vary
by approximately half a pound.

Length (in.) added to Lineup 
by Each End or Insulated 
Partition

1

/

2

Wide Island, 1 Display Level with Front Glass

Optional

Positions

28

(711)

COIL

C

L

Front

of

Case

COIL

FAN

MWG 

Electrical

(Optional Kit)

28

(711)

1

/

2

(140)

57 

7

/

8

(1470)

74 

5

/

8

(1895)

17

 

(432)

1

/

(57)

7

/

(149)

1

/

(89)

15

(382)

44

(1118)

1

/

4

(210)

3

/

4

(197)

11 

3

/

4

(298)

37 

3

/

8

(949)

17 

3

/

8

(441)

25 

1

/

2

(648)

Dimensions shown as inches and (mm).

NSF Certification

These merchandisers are manufactured to meet ANSI /National 
Sanitation Foundation (NSF ®) Standard #7 requirements. 

Отзывы: