GENERAL INFORMATION

 

 

MODEL DESCRIPTION

 

 

The ISCGG,  ISFGG  and  ISM(R)GG models are island, spot display merchandisers.  They are 
available as either remote type, which require a separate condensing unit connection, or self-
contained.   Each self-contained model will have it’s own condensing unit, factory installed 
beneath the display area of the case completely ready for operation when electrical service is 
connected.

 

 

The ISFGG  models are designed for dual-temperature operation; either Low temperature 
(frozen food) or Medium temperature (fresh meat, dairy, and delicatessen models).   The  
ISFGG will have upper glass on 4 sides.  The ISMGG  model has been designed for medium 
temperature operation and it will have the upper glass installed on all four sides. The ISFRGG  
will have curved glass on all sides.  The ISMRGG will have curved plexiglass on all sides.  The 
ISCGG models are designed for ice cream merchandizing.

 

 

The following table lists the standard models with a brief description of each, including the 
electrical requirements of the self-contained model.  Unless otherwise specified, the electrical 
requirements for all remote models will be 120 volt, 60 hertz (Hz).

 

 
 

MODEL ELECTRICAL DESCRIPTION 

 

 

MODEL DESCRIPTION 

ELECTRICAL 

SERVICE 

ISCGG-R 

Remote Type, Ice Cream 

 

ISMGG – R 

Remote Type,    Medium  Temperature 

 

ISFGG – R 

Remote Type,    Dual  Temperature, straight glass (1) 

 

ISFRGG – R 

Remote Type,    Dual  Temperature, curved glass (2) 

 

ISMRGG-R 

Remote Type, Medium Temperature, curved plexiglass    

ISMGG – B 

Self-Contained,   Medium  Temperature, straight glass   120 / 60 Hz / 1

 

ISFGG – B 

Self-Contained,   Dual  Temperature, straight glass (1) 

120 / 60 Hz / 1

 

ISFRGG – B 

Self-Contained,   Dual  Temperature, straight glass (2) 

120 / 60 Hz / 1

 

ISMRGG-B 

Self-Contained,   Medium  Temperature, curved 
plexiglass 

120 / 60 Hz / 1

 

ISCGG-D/G 

Self-Contained, Ice Cream  

208v / 230v / 60 Hz / 1

 

ISFGG – D/G 

Self-Contained,   Dual  Temperature (1) 

208v / 230v / 60 Hz / 1

 

ISFRGG – D/G 

Self-Contained,   Dual  Temperature (2) 

208v / 230v / 60 Hz / 1

 

 

APPLICATION

 

 

These models are designed for use only in air-conditioned stores where temperature is 75

°

F or 

less and relative humidity does not exceed 55%. 
 

 

 

  

Содержание ISCGG-D

Страница 1: ...m Temperature Remote and Self Contained Merchandisers P N OII ISF Merchandiser January 2006 First Call for help US and Canada 1 800 922 1919 Soporte T cnico y Asistencia M xico 01 800 522 1900 For a S...

Страница 2: ...ECTION 2 INSTALLATION PAGE 4 SECTION 3 REFRIGERATION PAGE 7 Self Contained Models SECTION 4 REFRIGERATION PAGE 9 Remote Models SECTION 5 ELECTRICAL PAGE 18 SECTION 6 REPLACEMENT PARTS LIST PAGE 21 SEC...

Страница 3: ...the standard models with a brief description of each including the electrical requirements of the self contained model Unless otherwise specified the electrical requirements for all remote models wil...

Страница 4: ...remove all packaging and shipping braces Remove all separately packed accessories such as kits shelves etc EXTERIOR LOADING These cases are not structurally designed to support excessive external load...

Страница 5: ...he condensate evaporation pan located beneath the case On remote models This water seal is formed by a moulded trap that requires drip piping to connect with floor drain The case is equipped with a 1...

Страница 6: ...Page 6...

Страница 7: ...l power has been connected The ISF and ISFG compressors are mounted on vibration springs which have been torqued down prior to shipment to prevent damage ALL LOWER BASE PANELS MUST BE IN PLACE WHEN TH...

Страница 8: ...OFF TIME 80 psig for R 22 54 psig for R 134a 70 c A refrigeration thermostat controls refrigeration temperature This is factory installed in the control panel Adjust this thermostat to maintain the di...

Страница 9: ...ator beneath the display pans After connections have been made seal this outlet thoroughly both on the inside and the outside An aerosol dispensed urethane type of insulation is recommended LINE SIZIN...

Страница 10: ...erature Adjust the valve as follows Attach two sensing probes either thermocouple or thermistor type to the evaporator One under the clamp holding the expansion valve bulb and the other securely taped...

Страница 11: ...field or factory installed must have a differential of 3 F to 6 F and have its sensing bulb located to monitor the air leaving the evaporator One thermostat per condensing unit is required and should...

Страница 12: ...ture to the corresponding refrigerant pressure e When the low pressure control is used to control refrigeration temperature set the cutout of the control to stop the compressor at the discharge air te...

Страница 13: ...service thermometer to the discharge honeycomb at the centre of the case Adjust the refrigeration control to maintain the discharge air temperature shown above e If these spot display refrigerators a...

Страница 14: ...do not have similar defrost frequencies and terminations fail safeguards with these spot display refrigerators The remote control kit will be factory installed below the display area of the spot disp...

Страница 15: ...ION HUSSMANN PART MANUFACT PART Liquid Line Solenoid Valve Sporlan A351 or B651 Refrigeration Thermostat 04 S 067 White Rogers 1710 4 On Off Switch 03 S 286 Cutler Hammer 7599K1 Defrost Timer 03 S 269...

Страница 16: ...PTION HUSSMANN PART MANUFACT PART Liquid Line Solenoid Valve Sporlan A351 or B651 Refrigeration Thermostat 04 S 067 White Rogers 1710 4 Disconnect Switch 03 S 286 Various 2PST Defrost Timer 03 S 269 P...

Страница 17: ...ion box located behind the removable base panel at the left hand end of the case SELF CONTAINED MODELS All electrical connections for self contained models will be made in the control panel of the cas...

Страница 18: ...G 8B 120V 60Hz 1 16 2 amps ISM G G 10B 120V 60Hz 1 ISF G G 10B 120V 60Hz 1 ISM G G 5 D G 208 230v 60 Hz 1 ISF G G 5 D G 208 230v 60 Hz 1 11 1 amps ISM G G 8 D G 208 230v 60 Hz 1 ISF G G 8 D G 208 230...

Страница 19: ...19 S 751 Defrost Heater 120v 12 5 amps 1500 watts 6 380064 Expansion Valve Sporlan EGV 1 2 Z 7 261933 04 S 067 Refrigeration Thermostat White Rogers 1710 4 8 294226 03 S 286 Disconnect Switch 9 04744...

Страница 20: ...2 S 628 Compressor Copeland KAMB 0075 CAA 299 18 112033 25 S 114 Condenser HeatCraft Inc 0271099B00J 19 314580 High Pressure Control TI 26PSXXX WC400 K32 K 20 314573 Heater Condensate NOTE Items 1 thr...

Страница 21: ...61933 04 S 067 Refrigeration Thermostat White Rogers 1710 4 6 294226 03 S 286 Disconnect Switch 7 047449 03 S 559 Defrost Timer Paragon 8242 0B 8 059995 Contactor Furnas 42BE35AF106 3P 115v 30amp 9 20...

Страница 22: ...5 322013 Defrost Heater 230v 2 0 amps 200 460 watts 6 380064 Expansion Valve Sporlan EGV 1 2 Z 7 261933 04 S 067 Refrigeration Thermostat White Rogers 1710 4 8 000582 Disconnect Switch 9 106236 03 S...

Страница 23: ...ITEM HUSSMANN PART Continued ISF D ISFG K ISF K ISFGG D ISFG D ISFGG K 17 381616 02 S 638 Compressor Copeland KAMA 0075 TAC 299 18 112033 25 S 114 Condenser HeatCraft Inc 0271099B00J 19 314580 High Pr...

Страница 24: ...5799 19 S 752 ISMG 8 ISMG 10 920057 19 S 758 ISMGG 5 315799 ISMGG 8 ISMGG 10 920057 ISFG 5 920057 375030 19 S 767 820442 19 S 754 ISFG 8 857853 19 S 773 375030 857854 19 S 774 ISFG 10 920057 x2 375030...

Страница 25: ...AND CLEANING Long life and satisfactory performance of any equipment is dependent upon the care given to it To ensure long life proper sanitation and minimum maintenance the fixture should be thorough...

Страница 26: ...anufacturer s directions To preserve the exterior finish of the fixture use warm water and a mild detergent DO NOT USE ABRASIVE CLEANERS OR STEEL WOOL SCOURING PADS TO CLEAN THE FIXTURE AS THESE WILL...

Страница 27: ...er cells of the honeycomb on the left hand end and lift it up gently The bottom of the honeycomb will begin to show Twist screw driver upwards away from the front of the case to slip the honeycomb out...

Страница 28: ...To remove corner caps simply hold part and pull upwards Corner caps naturally fit tight to prevent undesirable removal To remove glass just pull upwards The nosing panel is a snap fit therefore a tool...

Страница 29: ...HEATER EVAPORATOR FAN M DISCHARGE NOSING ANTI SWEAT HEATER ELECTRICAL BOX PWR SWITCH BLACK LINE1 WHITE NETURAL BLACK LINE2 BLUE BLK BLK WHT WHT BLK BLK BLK BLK BLK BLK USAGE ISFG GG 5 D G 10D G ISCG...

Страница 30: ...2 4 3 N c L1 L2 L3 T1 T2 T3 C R S N 1 2 3 S PROTECTOR FUSEITE CURRENT RELAY START CAPACITOR CONDENSER FAN 3 4 HP COMPRESSOR MOTOR THERMOSTAT HIGH PRESSURE SAFETY CONTROL CONTACTOR TIMER CONDENSATE PAN...

Страница 31: ...1 64 x 1 2 4 3 N c L1 L2 L3 T1 T2 T3 THERMOSTAT HIGH PRESSURE SAFETY CONTROL CONTACTOR TIMER CONDENSATE PAN HEATER EVAPORATOR FAN M DISCHARGE NOSING ANTI SWEAT HEATER ELECTRICAL BOX PWR SWITCH BLACK W...

Страница 32: ...PRESSURE SAFETY CONTROL CONTACTOR TIMER CONDENSATE PAN HEATER EVAPORATOR FAN M DISCHARGE NOSING ANTI SWEAT HEATER ELECTRICAL BOX PWR SWITCH BLACK WHITE GROUND BLUE BLK BLK WHT WHT WHT BLK BLK BLK WHT...

Страница 33: ...RESSURE SAFETY CONTROL CONTACTOR TIMER CONDENSATE PAN HEATER EVAPORATOR FAN M DISCHARGE NOSING ANTI SWEAT HEATER ELECTRICAL BOX PWR SWITCH BLACK LINE1 WHITE NETURAL BLACK LINE2 BLUE BLK BLK WHT WHT BL...

Отзывы: