background image

RLNIE  with 

Innovator Doors

Technical Data Sheet

2 of 10

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

RLNIE

General

Case Length

99 

3

/

4

(2530)

Maximum O/S dimension of case back to front  (

Includes bumpers)

72 

3

/

8

(1837)

Width of skid rail

1

/

2

(114)

Width of Bottom Support

6 (152)

Stub-up area between front skid rail and splashguard

3

/

8

(162)

Electrical Service

*

RH end of case to the center of nearest knockout

4 (102)

RH end of case to the center of LH knockout

88 

3

/

8

(2246)

Back O/S of case to center of knockout 

(Electrical Field Wiring Connection Point is at terminal.)

70 

1

/

8

(1782)

Waste Outlet

RH end of case to center of waste outlet in back of case

38 

1

/

8

(969)

RH end of case to center of waste outlet in front of case

54 

1

/

4

(1378)

Back O/S of case to center of waste outlet

63 

1

/

8

(1604)

Water Seal

Edge of water seal to center of waste outlet

11 (279)

Outside diameter of drip piping

1

/

4

(32)

Field installed water seal outlets, tees, and connectors are shipped with case.

Refrigeration Outlet

RH end of case to center of refrigeration outlet

3

/

8

(137)

Back O/S of case to center of refrigeration outlet

60 

5

/

8

(1541)

Outside bottom front supports from end of case

3

/

4

(171)

Distance between centerlines of front supports

48 (1219)

6

 

(152)

Water Seal 

(See Note**)

Waste Outlet

Electrical Wireway

Electrical Wireway

Waste Outlet

Electr

ical Wire

w

a

y

88 

3

/

(2246)

1

/

(232)

Relay & Terminal 
Block Location

Refrigeration 
Outlet

60 

5

/

(1541)

63 

1

/

(1604)

70 

1

/

(1782)

72 

3

/

(1837)

3

 

(76)

4

 

(102)

54 

1

/

(1378)

5

/

(142)

38 

1

/

(969)

99 

3

/

(2530)

48

 

(1219)

Main Field Connection 

Electrical Terminal Block

REAR OF CASE

FRONT OF CASE

Relay & 
Terminal 
Block 
Location

Relay & Terminal 
Block Location

Engineering

Plan Views

Reach-in 

Narrow Island

Unitized End Case

Dimensions shown as in. & (mm).

6-2003

Содержание IMPACT RLNIE

Страница 1: ...74033 Standard Non adjustable 2 Defrost Thermostat CT 4440726 C Optional Adjustable Refrigeration Thermostat 3 D 0344662 Defrost Limit Thermostat 4 CT 4440261 E 0461814 Relay Control Thermostat or 5 F...

Страница 2: ...3 1 8 1604 Water Seal Edge of water seal to center of waste outlet 11 279 Outside diameter of drip piping 1 1 4 32 Field installed water seal outlets tees and connectors are shipped with case Refriger...

Страница 3: ...S Low Pressure Backup Control FF IC CI CO Temp F 18 34 26 45 Indoor Unit Only Pressure Defrost Termination Temp F Not Recommended Use a Temperature Pressure Chart to determine PSIG conversions PHYSICA...

Страница 4: ...weat Heaters on fan circuit 120V 50 60Hz Standard 1 67 200 220V 50 60Hz Export 0 87 200 Minimum Circuit Ampacity 120V 60Hz Standard 15 73 120V 50Hz Standard 16 43 220V 60Hz Export 8 45 220V 50Hz Expor...

Страница 5: ...Circuits Electric Defrost standard RLNIE Front and Rear Compartment 24 25 12 FANS A S 120V LIGHTS Neutral FANS A S Neutral Permanent Internal Jumpers R P W BR OR R R R B B R R B P 2P B B OR B 2P Y Rem...

Страница 6: ...urple 2 Bands DB Dark Blue B Black BR Brown Y Yellow OR Orange W White Fan and Heater Circuits Electric Defrost standard RLNIE End Compartment 24 25 12 FANS A S 120V LIGHTS Neutral FANS A S Neutral Pe...

Страница 7: ...8 10 11 12 13 14 16 17 20 21 22 24 25 26 Ph B 208v Ph C 208v Fans AS 120v Lights 120v Fans AS Ntrl Lights Ntrl RLNIE Wiring Diagram for Electric Defrost Front of Case Three door Frame End of Case Two...

Страница 8: ...Condensing Unit CIRCLED NUMBERS PARTS LIST ITEM NUMBERS THESE ARE MARKER COLORS WIRE MAY VARY R Red P Purple 2P Purple 2 Bands DB Dark Blue B Black BR Brown Y Yellow OR Orange W White 24 25 12 FANS A...

Страница 9: ...NUMBERS PARTS LIST ITEM NUMBERS THESE ARE MARKER COLORS WIRE MAY VARY R Red P Purple 2P Purple 2 Bands DB Dark Blue B Black BR Brown Y Yellow OR Orange W White 24 25 12 FANS A S 120V LIGHTS Neutral FA...

Страница 10: ...22 24 25 26 10 11 12 13 14 16 17 20 21 22 24 25 26 Lights 120 Fans AS Ntrl Lights Ntrl Front of Case Three door Frame End Case Two door Frame Rear of Case Three door Frame Gas Defrost Sequence Low Tem...

Отзывы: