background image

RLNIE  with 

Innovator Doors

Technical Data Sheet

10 of 10

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Fans & AS (120v)

Light (120v)

Light (Neutral)

Fans & AS (Neutral)

Fans & AS (120v)

Light (120v)

Light (Neutral)

Fans & AS (Neutral)

Fans & AS (120v)

Light (120v)

Light (Neutral)

Fans & AS (Neutral)

Fans & AS (120v)

Light (120v)

Fans & AS (Neutral)

Light (Neutral)

RLNIE 

Wir

ing Diag

ram f

o

r Gas Defrost

Main Field Electr

ical Connection Rear of Case

(T

er

minal Bloc

k Located in RH Doorfr

a

me wire

w

a

y)

F

ront of Case

(Three door F

rame)

End Case

(T

w

o

 door F

rame)

Rear of Case

(Three door F

rame)

F

ans & AS (120)

Standard RL ter

m

inal b

loc

ks 

in door fr

ame wire

w

a

y.

Ne

w ter

m

inal b

loc

k located in 

RH door fr

ame wire

w

a

y.

10

11

12

13

14

16

17

20

21

22

24

25

26

10

11

12

13

14

16

17

20

21

22

24

25

26

10

11

12

13

14

16

17

20

21

22

24

25

26

Lights (120)

F

ans & AS (Ntr

l)

Lights (Ntr

l)

F

ront of Case

(Three door F

rame)

End Case

(T

w

o

 door F

rame)

Rear of Case

(Three door F

rame)

Gas Defr

ost Sequence - Lo

w T

emperatur

e

1.

Defrost v

apor enters e

v

aporator causing a rise in temperature. At about 35°F the Control Relay Thermostat 

(5)

closes the F

an Relay Coil 

(7) 

and Control Relay Coil 

(6) 

circuit.  The Coil opens the F

an, Door Heater

,

and Frame Heater circuits, while ener

gizing the Drain P

an Heater 

(9)

.

2.

If the Drain P

an Heater 

(9)

raises internal air temperature abo

v

e 90°F

, the Heater Limit Thermostat 

(4) 

will open.

3.

When the defrost timer ends a defrost period, the e

v

aporator temperature will start to f

all.  At about 20°F

, the Control

Relay Thermostat will open, de-ener

gizing the Control Relay Coil and F

an Relay Coil 

(7). 

Control and F

an Relay’

s

will open the Drain P

an Heater circuits, and will close the F

an, Door Heater

, and Frame Heater circuits.

Содержание IMPACT RLNIE

Страница 1: ...74033 Standard Non adjustable 2 Defrost Thermostat CT 4440726 C Optional Adjustable Refrigeration Thermostat 3 D 0344662 Defrost Limit Thermostat 4 CT 4440261 E 0461814 Relay Control Thermostat or 5 F...

Страница 2: ...3 1 8 1604 Water Seal Edge of water seal to center of waste outlet 11 279 Outside diameter of drip piping 1 1 4 32 Field installed water seal outlets tees and connectors are shipped with case Refriger...

Страница 3: ...S Low Pressure Backup Control FF IC CI CO Temp F 18 34 26 45 Indoor Unit Only Pressure Defrost Termination Temp F Not Recommended Use a Temperature Pressure Chart to determine PSIG conversions PHYSICA...

Страница 4: ...weat Heaters on fan circuit 120V 50 60Hz Standard 1 67 200 220V 50 60Hz Export 0 87 200 Minimum Circuit Ampacity 120V 60Hz Standard 15 73 120V 50Hz Standard 16 43 220V 60Hz Export 8 45 220V 50Hz Expor...

Страница 5: ...Circuits Electric Defrost standard RLNIE Front and Rear Compartment 24 25 12 FANS A S 120V LIGHTS Neutral FANS A S Neutral Permanent Internal Jumpers R P W BR OR R R R B B R R B P 2P B B OR B 2P Y Rem...

Страница 6: ...urple 2 Bands DB Dark Blue B Black BR Brown Y Yellow OR Orange W White Fan and Heater Circuits Electric Defrost standard RLNIE End Compartment 24 25 12 FANS A S 120V LIGHTS Neutral FANS A S Neutral Pe...

Страница 7: ...8 10 11 12 13 14 16 17 20 21 22 24 25 26 Ph B 208v Ph C 208v Fans AS 120v Lights 120v Fans AS Ntrl Lights Ntrl RLNIE Wiring Diagram for Electric Defrost Front of Case Three door Frame End of Case Two...

Страница 8: ...Condensing Unit CIRCLED NUMBERS PARTS LIST ITEM NUMBERS THESE ARE MARKER COLORS WIRE MAY VARY R Red P Purple 2P Purple 2 Bands DB Dark Blue B Black BR Brown Y Yellow OR Orange W White 24 25 12 FANS A...

Страница 9: ...NUMBERS PARTS LIST ITEM NUMBERS THESE ARE MARKER COLORS WIRE MAY VARY R Red P Purple 2P Purple 2 Bands DB Dark Blue B Black BR Brown Y Yellow OR Orange W White 24 25 12 FANS A S 120V LIGHTS Neutral FA...

Страница 10: ...22 24 25 26 10 11 12 13 14 16 17 20 21 22 24 25 26 Lights 120 Fans AS Ntrl Lights Ntrl Front of Case Three door Frame End Case Two door Frame Rear of Case Three door Frame Gas Defrost Sequence Low Tem...