background image

1

/

2

 

(165)

P1X49MOB-B

29 

7

/

8

(760)

30 

3

/

8

(773)

34 

7

/

 

(883)

46 

1

/

 

(1174)

16 

3

/

4

(425)

49 

3

/

4

(1263)

25 

1

/

2

(648)

17 

3

/

8

(441)

16 

1

/

2

(420)

F

A
N

C
O

I

L

3

/

16

(5)

REFRIGERATION DATA

Note:

This data is based on store temperature

and humidity that does not exceed 75°F and
55% R.H.  Schedule defrost at night while
lights are off.

P1X49MOB-B

Discharge Air °F

31

Evaporator °F

24

Unit Sizing °F

22

Btu/hr/case

594

DEFROST DATA

P1X49MOB-B

Frequency (hr)

8

Defrost Water (lb/ft/day)

NA

(±15% based on case configuration and
product loading.)

O

FFTIME

P1X49MOB-B

Temp Term °F

43°F

Failsafe Minutes

35

E

LECTRIC OR

G

AS

Not Recommended

Standard Defrost Thermostat

Close on rise:    close 43°F — open 33°F

CONVENTIONALCONTROLS

Low Pressure Backup Control

P1X49MOB-B

CI/CO**

14 / 4°F

Indoor Unit Only, Pressure Defrost
Termination**

48°F

**Use a Temperature Pressure Chart to deter-
mine PSIG conversions.

PHYSICAL DATA

Drip Pipe (in.)

1

/

2

Liquid Line (in.)

3

/

8

Suction Line (in.)

5

/

8

Estimated Charge (lbs)***

P1X49MOB-B

6 ft

3.6

8 ft

4.0

***This is an average for all refrigerant types
actual refrigerant charge may vary by approx-
imately half a pound.

Length (in.) Added to Lineup  by Each
End or Insulated  Partition

1

/

2

Impact  

P1X49MOB-B

Bulk Produce, Self-Contained

Single Deck,  49 Inch High Back,  1 Display Level
Mobile Self-Contained

Dimensions shown as inches and (mm).

3 of 6

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P/N 0457222