Multi-deck, 3 or 4 Display Levels

NSF Certification

These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF 

®

) Standard #7 requirements. 

Impact  

M2E

Meat, Delicatessen,

and Pre-cut Produce

REFRIGERATION DATA

Note: 

This data is based on store temperature

and humidity that does not exceed 75

°

F and

55% R.H. 

M2E

Discharge Air (°F)

29

Evaporator (°F)

21

Unit Sizing (°F)

19

Btu/hr/ft*

M2E

Parallel

1055

Conventional

1135

*For all refrigeration equipment other than
Hussmann, use conventional Btu values.

DEFROST DATA

M2E

Frequency (hr)

6

Defrost Water (lb/ft/day)

6

(± 15% 

based on case configuration and

product loading).

O

FF

T

IME

M2E

Temp Term 

(

°

F

)

48

°

F

Failsafe (minutes)

30

E

LECTRIC OR

G

AS

Not Recommended 

Standard Defrost Thermostat 

Close on rise: close 48°F  —  open 33°F 

CONVENTIONAL CONTROLS

Low Pressure Backup Control

M2E

CI/CO

**

14°F / 4°F

Indoor Unit Only, Pressure Defrost
Termination**

48°F

**Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

2

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

7

/

8

Estimated Charge (lb)***
8 ft 

2.3

12 ft 

3.3

***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.

Length (in.) added to Lineup by Each 
End or Insulated Partition

1

/

2

The M2 has been discontinued.

Содержание IMPACT M2E

Страница 1: ...table 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with li...

Страница 2: ...of electrical raceway 34 1 2 878 34 1 2 878 Waste Outlet C Left hand end of case to the center of waste outlet 72 1 4 1835 72 1 4 1835 D Right hand end of case to the center of waste outlet 24 1 8 61...

Страница 3: ...Conventional 1135 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA M2E Frequency hr 6 Defrost Water lb ft day 6 15 based on case configuration and product l...

Страница 4: ...icient Fans 120V 60Hz 0 72 0 98 With Export Fans 230V 50Hz 0 76 1 04 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Standard Lighting 8 ft 12 ft 8 ft 12 ft 1 Row...

Страница 5: ...must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 2 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Case...

Страница 6: ...E OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 R R R 5 Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL...

Страница 7: ...N Bridgeton MO 63044 2483 U S A The shelf configuration of these merchandisers is critical Shelf Configuration for M2E Top shelf must be 14 inches wide and placed at a 45 angle This shelf position app...

Отзывы: