Hussmann IMPACT M2E Скачать руководство пользователя страница 2

8 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

96 

3

/

8

(2448)

144 

1

/

2

(3670)

Maximum outside dimension of case back to front 

(includes bumper)

46 

1

/

2

(1182)

46 

1

/

2

(1182)

Back of case to front of splash guard

38 

7

/

8

(986)

38 

7

/

8

(986)

Back of case to outside edge of front skid rail

29 

1

/

4

(743)

29 

1

/

4

(743)

Width of skid rail

1

/

2

(114)

1

/

2

(114)

Right-hand end of case to inside edge of external support

1

/

2

(140)

1

/

2

(140)

Distance between edges of external support and center support

40 

5

/

8

(1032)

40 

5

/

8

(1032)

Distance between edges of center supports

NA

44 (1118)

Stub-up area between front skid rail and splash guard

7

/

8

(199)

7

/

8

(199)

Electrical Service                         

(Electrical Field Wiring connection point)

(B)

Right-hand end of case to center of farthest knockout

88 

3

/

8

(2245)

136 

1

/

2

(3467) 

Back outside of case to center of knockout

34 

5

/

8

(881)

34 

5

/

8

(881)

Length of electrical raceway

34 

1

/

(878)

34 

1

/

(878)

Waste Outlet

(C)

Left-hand end of case to the center of waste outlet

72 

1

/

4

(1835)

72 

1

/

4

(1835)

(D)

Right-hand end of case to the center of waste outlet

24 

1

/

8

(613)

72 

1

/

4

(1835)

Back outside of case to center of waste outlet

27 

5

/

8

(702)

27 

5

/

8

(702)

Water Seal

Edge of water seal to center of waste outlet

4 (102)

4 (102)

Outside diameter of the drip pipe

1

/

(38)

1

/

(38)

*

Note:

Water seal outlet must clear front skid rail.

M2 & M2G water seal rotation in forward direction only, due to low base.

Refrigeration Outlet

(E)

Right-hand end of case to center of refrigeration outlet

9 (230)

9 (230)

Back of case to center of refrigeration outlet

30 

5

/

(778)

30 

5

/

(778)

2 of 7

Engineering

Plan Views

B

C

Electrical

Waste Outlet

4

(102)

34 

5

/

8

(881)

46

 

1

/

2

(1182)

38

 

7

/

8

(986)

29

 

1

/

4

(743)

30

 

5

/

8

(778)

E

27

 

5

/

8

(703)

Refrigeration

A

Water Seal

 (See Note*)

M2E

Skid/ External Base

Front

D

7

 

7

/

8

 

(199)

5

 

1

/

(140)

Dimensions shown as inches and (mm).

M2E 

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Meat, Delicatessen 

and Precut Produce

09-2003

Содержание IMPACT M2E

Страница 1: ...table 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with li...

Страница 2: ...of electrical raceway 34 1 2 878 34 1 2 878 Waste Outlet C Left hand end of case to the center of waste outlet 72 1 4 1835 72 1 4 1835 D Right hand end of case to the center of waste outlet 24 1 8 61...

Страница 3: ...Conventional 1135 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA M2E Frequency hr 6 Defrost Water lb ft day 6 15 based on case configuration and product l...

Страница 4: ...icient Fans 120V 60Hz 0 72 0 98 With Export Fans 230V 50Hz 0 76 1 04 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Standard Lighting 8 ft 12 ft 8 ft 12 ft 1 Row...

Страница 5: ...must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 2 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Case...

Страница 6: ...E OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 R R R 5 Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL...

Страница 7: ...N Bridgeton MO 63044 2483 U S A The shelf configuration of these merchandisers is critical Shelf Configuration for M2E Top shelf must be 14 inches wide and placed at a 45 angle This shelf position app...

Отзывы: