background image

4 of 8

M5X-GEP 

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Impact 

Excel

M5X-GEP

Meat and Delicatessen

Electrical Data

4 ft

6 ft

8 ft

10 ft

12 ft

Number of Fans – 12W

2

4

2

6

Number of Fans – 7W

4

4

Amperes

Watts

4 ft

6 ft

8 ft

10 ft

12 ft

4 ft

6 ft

8 ft

10 ft

12 ft

Evaporator Fans

120V

60Hz

Standard

1.30

2.00

2.60

3.30

3.90

100

156

200

256

300

120V

50Hz

Standard

1.50

2.20

3.00

3.70

4.50

114

168

228

282

342

230V

60Hz

Export

0.66

1.00

1.32

1.66

1.98

100

156

200

256

300

230V

50Hz

Export

0.76

1.12

1.52

1.88

2.28

114

168

228

282

342

120V

60Hz

Energy Efficient

0.60

0.76

1.20

1.36

1.80

36

56

72

92

108

230V

60Hz

Energy Efficient

0.30

0.40

0.60

0.70

0.90

36

56

72

92

108

Minimum Circuit Ampacity

120V

60Hz

Standard

1.50

2.20

2.80

3.50

4.10

120V

50Hz

Standard

1.70

2.40

3.20

3.90

4.70

230V

60Hz

Export

0.86

1.20

1.52

1.86

2.18

230V

50Hz

Export

0.96

1.32

1.72

2.08

2.48

120V

60Hz

Energy Efficient

0.80

0.96

1.40

1.56

2.00

230V

60Hz

Energy Efficient

0.50

0.60

0.80

0.90

1.10

Maximum Over Current Protection 120V

20

20

20

20

20

Maximum Over Current Protection 230V

15

15

15

15

15

Standard Lighting (T-8 fluorescent)

1 Row Canopy

0.26

0.51

0.51

0.77

0.77

30

59

59

85

85

Optional Lighting (T-8 fluorescent)

Additional 1 Row Canopy

0.26

0.51

0.51

0.77

0.77

30

59

59

85

85

Additional 2 Row Canopy

0.51

1.02

1.02

1.54

1.54

59

118

118

170

170

Additional 3 Row Canopy

0.77

1.53

1.53

2.31

2.31

89

177

177

255

255

1 Row Rail Light

NA — Glass front does not accept rail light

Optional Shelf Lighting (T-8 fluorescent)

4 Rows of Shelves

1.02

2.04

2.04

3.08

3.08

118

236

236

340

340

5 Rows of Shelves

1.28

2.55

2.55

3.85

3.85

148

295

295

425

425

Optional Always*Bright LED Lighting

4 Rows of Shelves

0.47

0.68

0.93

1.15

1.40

56

82

112

138

168

5 Rows of Shelves

0.57

0.83

1.13

1.38

1.69

68

99

136

166

203

120V Lighting Circuit Total = Standard Li Total Optional Li Optional Shelf Lighting

230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52

Содержание Impact Excel M5X-GEP

Страница 1: ...Ft and 10 Ft Only A 7W Standard Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 F...

Страница 2: ...1 1 2 1054 29 1 2 749 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electr...

Страница 3: ...to determine PSIG conversions Estimated Charge lb M5X GEP 4 ft 1 9 6 ft 2 5 8 ft 3 7 10 ft 4 4 12 ft 5 1 This is an average for all refrigerant types Actual refrigerant charge may vary by approximate...

Страница 4: ...2 48 120V 60Hz Energy Efficient 0 80 0 96 1 40 1 56 2 00 230V 60Hz Energy Efficient 0 50 0 60 0 80 0 90 1 10 Maximum Over Current Protection 120V 20 20 20 20 20 Maximum Over Current Protection 230V 1...

Страница 5: ...m ARI Total Display Area 3 Sq Ft Ft 4 40 ft2 ft 1 34 m2 m Shelf Area 4 Sq Ft Ft 8 36 ft2 ft 2 55 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 AR...

Страница 6: ...Three Row Canopy Connector 4 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 3 Row Canopy B 4 ft 6 ft...

Страница 7: ...nents must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Five Rows of Shelves 4 ft case...

Страница 8: ...R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNIN...

Отзывы: