4 of 8
M5X-GEP
Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact
Excel
M5X-GEP
Meat and Delicatessen
Electrical Data
4 ft
6 ft
8 ft
10 ft
12 ft
Number of Fans – 12W
2
—
4
2
6
Number of Fans – 7W
—
4
—
4
—
Amperes
Watts
4 ft
6 ft
8 ft
10 ft
12 ft
4 ft
6 ft
8 ft
10 ft
12 ft
Evaporator Fans
120V
60Hz
Standard
1.30
2.00
2.60
3.30
3.90
100
156
200
256
300
120V
50Hz
Standard
1.50
2.20
3.00
3.70
4.50
114
168
228
282
342
230V
60Hz
Export
0.66
1.00
1.32
1.66
1.98
100
156
200
256
300
230V
50Hz
Export
0.76
1.12
1.52
1.88
2.28
114
168
228
282
342
120V
60Hz
Energy Efficient
0.60
0.76
1.20
1.36
1.80
36
56
72
92
108
230V
60Hz
Energy Efficient
0.30
0.40
0.60
0.70
0.90
36
56
72
92
108
Minimum Circuit Ampacity
120V
60Hz
Standard
1.50
2.20
2.80
3.50
4.10
120V
50Hz
Standard
1.70
2.40
3.20
3.90
4.70
230V
60Hz
Export
0.86
1.20
1.52
1.86
2.18
230V
50Hz
Export
0.96
1.32
1.72
2.08
2.48
120V
60Hz
Energy Efficient
0.80
0.96
1.40
1.56
2.00
230V
60Hz
Energy Efficient
0.50
0.60
0.80
0.90
1.10
Maximum Over Current Protection 120V
20
20
20
20
20
Maximum Over Current Protection 230V
15
15
15
15
15
Standard Lighting (T-8 fluorescent)
1 Row Canopy
0.26
0.51
0.51
0.77
0.77
30
59
59
85
85
Optional Lighting (T-8 fluorescent)
Additional 1 Row Canopy
0.26
0.51
0.51
0.77
0.77
30
59
59
85
85
Additional 2 Row Canopy
0.51
1.02
1.02
1.54
1.54
59
118
118
170
170
Additional 3 Row Canopy
0.77
1.53
1.53
2.31
2.31
89
177
177
255
255
1 Row Rail Light
NA — Glass front does not accept rail light
Optional Shelf Lighting (T-8 fluorescent)
4 Rows of Shelves
1.02
2.04
2.04
3.08
3.08
118
236
236
340
340
5 Rows of Shelves
1.28
2.55
2.55
3.85
3.85
148
295
295
425
425
Optional Always*Bright LED Lighting
4 Rows of Shelves
0.47
0.68
0.93
1.15
1.40
56
82
112
138
168
5 Rows of Shelves
0.57
0.83
1.13
1.38
1.69
68
99
136
166
203
120V Lighting Circuit Total = Standard Li Total Optional Li Optional Shelf Lighting
230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52