background image

2 of 8

M5X-GEP 

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Engineering

Plan Views

Dimensions shown as inches and (mm).

Meat and Produce

10-2004

NOTE: Case-to-Case Electrical Connections 
are made IN FRONT OF SPLASHGUARD. 

3

/

(120)

Splashguard

31 

5

/

(804)

42

 

(1064)

A

41 

1

/

(1054)

3 In. 

(77 mm)

 

Required 

Air Gap

Refrigeration 

Outlet

Electrical 

Stub Up Area 

6 x 6 

(152x152)

 

Waste Outlet

Waste Outlet

FRONT

26 

1

/

(665)

B

D

8

 

(203)

1

/

(115)

12 

1

/

(307)

41 

1

/

(1054)

43 

7

/

(1114)

C

Wireway

3

/

(120)

26 

1

/

(673)

1

/

(108)

24

 

(612)

33 

1

/

(851)

Electrical 
Field 
Connection

30 

1

/

(768)

M5X

4 ft

6 ft

8 ft

10 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

48 

3

/

8

(1229)

72 

3

/

8

(1838)

96 

3

/

8

(2448)

120 

1

/

2

(3061)

144 

1

/

2

(3670)

(Each end and insulated partition adds 1 

1

/

in. (38 mm) to case line up.)

Maximum O/S dimension of case back to front 

(includes bumper)

42 (1064)

42 (1064)

42 (1064)

42 (1064)

42 (1064)

Back of case to front of splashguard

33 

1

/

(851)

33 

1

/

(851)

33 

1

/

(851)

33 

1

/

(851)

33 

1

/

(851))

Back of case to O/S edge of front leg

30 

1

/

(768)

30 

1

/

(768)

30 

1

/

(768)

30 

1

/

(768)

30 

1

/

(768)

Distance between edges of external legs and center legs

NA

29 

1

/

(750)

41 

1

/

(1054)

29 

1

/

(749)

41 

1

/

(1054)

Distance between edges of center legs

NA

NA

NA

43 

7

/

(1114)

43 

7

/

(1114)

Distance between front legs and splashguard

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

Electrical Service             

(Electrical Field Wiring connection point)

(B)

RH End of case to center of stub up area

36 

1

/

(921)

60 

1

/

(1530)

84 

1

/

(2140)

108 

1

/

(2750)

132 

3

/

(3363)

Back of case to center of stub up area

24 (612)

24 (612)

24 (612)

24 (612)

24 (612)

Length of electrical wireway

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

(C)

RH End of case to LH end of wireway

42 

1

/

(1070)

66 

1

/

(1680)

90 

1

/

(2289)

114 

1

/

(2902)

138 

1

/

(3511)

Waste Outlets  

(One each end)

(D)

RH End of case to the center of LH waste outlet

36 

1

/

(921)

60 

1

/

(1530)

84 

1

/

(2140)

108 

1

/

(2750)

132 

3

/

(3363)

RH End of case to the center of RH waste outlet

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

Back O/S of case to center of waste outlets

31 

5

/

(804)

31 

5

/

(804)

31 

5

/

(804)

31 

5

/

(804)

31 

5

/

(804)

Schedule 40 PVC drip pipe

1

/

(32)

1

/

(32)

1

/

(32)

1

/

(32)

1

/

(32)

Refrigeration Outlet

Back of case to center of refrigeration outlet

26 

1

/

(665)

26 

1

/

(665)

26 

1

/

(665)

26 

1

/

(665)

26 

1

/

(665)

RH end of case to center of refrigeration outlet

8  (203)

8  (203)

8  (203)

8  (203)

8  (203)

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

4

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

7

/

8

Wireway

Содержание Impact Excel M5X-GEP

Страница 1: ...Ft and 10 Ft Only A 7W Standard Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 F...

Страница 2: ...1 1 2 1054 29 1 2 749 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electr...

Страница 3: ...to determine PSIG conversions Estimated Charge lb M5X GEP 4 ft 1 9 6 ft 2 5 8 ft 3 7 10 ft 4 4 12 ft 5 1 This is an average for all refrigerant types Actual refrigerant charge may vary by approximate...

Страница 4: ...2 48 120V 60Hz Energy Efficient 0 80 0 96 1 40 1 56 2 00 230V 60Hz Energy Efficient 0 50 0 60 0 80 0 90 1 10 Maximum Over Current Protection 120V 20 20 20 20 20 Maximum Over Current Protection 230V 1...

Страница 5: ...m ARI Total Display Area 3 Sq Ft Ft 4 40 ft2 ft 1 34 m2 m Shelf Area 4 Sq Ft Ft 8 36 ft2 ft 2 55 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 AR...

Страница 6: ...Three Row Canopy Connector 4 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 3 Row Canopy B 4 ft 6 ft...

Страница 7: ...nents must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Five Rows of Shelves 4 ft case...

Страница 8: ...R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNIN...

Отзывы:

Похожие инструкции для Impact Excel M5X-GEP