background image

2 of 9

C6X-E

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Engineering

Plan Views

Dimensions shown as in. and (mm).

Convertible

09-2005

NOTE: Case-to-Case Electrical Connections 
are made IN FRONT OF SPLASHGUARD. 

3

/

(120)

Splashguard

31 

5

/

(804)

42

 

(1064)

A

41 

1

/

(1054)

3 In. 

(77 mm)

 

Required 

Air Gap

Refrigeration 

Outlet

Electrical 

Stub Up Area 

6 x 6 

(152x152)

 

Waste Outlet

Waste Outlet

FRONT

26 

1

/

(665)

B

D

8

 

(203)

1

/

(115)

12 

1

/

(307)

41 

1

/

(1054)

43 

7

/

(1114)

C

Wireway

3

/

(120)

26 

1

/

(673)

1

/

(108)

24

 

(612)

33 

1

/

(851)

Electrical 
Field 
Connection

30 

1

/

(768)

C6X

4 ft

6 ft

8 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

48 

3

/

8

(1229)

72 

3

/

8

(1838)

96 

3

/

8

(2448)

144 

1

/

2

(3670)

(Each end and insulated partition adds 1 

1

/

in. (38 mm) to case line up.)

Maximum O/S dimension of case back to front 

(includes bumper)

42 (1064)

42 (1064)

42 (1064)

42  (1064)

Back of case to front of splashguard

33 

1

/

(851)

33 

1

/

(851)

33 

1

/

(851)

33 

1

/

(851)

Back of case to O/S edge of front leg

30 

1

/

(768)

30 

1

/

(768)

30 

1

/

(768)

30 

1

/

(768)

Distance between edges of external legs and center legs

NA

29 

1

/

(750)

41 

1

/

(1054)

41 

1

/

(1054)

Distance between edges of center legs

NA

NA

NA

43 

7

/

(1114)

Distance between front legs and splashguard

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

Electrical Service             

(Electrical Field Wiring connection point)

(B)

RH End of case to center of stub up area

36 

1

/

(921)

60 

1

/

(1530)

84 

1

/

(2140)

132 

3

/

(3363)

Back of case to center of stub up area

24 (612)

24 (612)

24 (612)

24 (612)

Length of electrical wireway

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

(C)

RH End of case to LH end of wireway

42 

1

/

(1070)

66 

1

/

(1680)

90 

1

/

(2289)

138 

1

/

(3511)

Waste Outlets  

(One each end)

(D)

RH End of case to the center of LH waste outlet

36 

1

/

(921)

60 

1

/

(1530)

84 

1

/

(2140)

132 

3

/

(3363)

RH End of case to the center of RH waste outlet

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

Back O/S of case to center of waste outlets

31 

5

/

(804)

31 

5

/

(804)

31 

5

/

(804)

31 

5

/

(804)

Schedule 40 PVC drip pipe

1

/

4

(32)

1

/

4

(32)

1

/

4

(32)

1

/

4

(32)

Refrigeration Outlet

Back of case to center of refrigeration outlet

26 

1

/

(665)

26 

1

/

(665)

26 

1

/

(665)

26 

1

/

(665)

RH end of case to center of refrigeration outlet

8  (203)

8  (203)

8  (203)

8  (203)

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

4

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

7

/

8

Wireway

Содержание Impact Excel C6X-E

Страница 1: ... Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part Description Wiring Item THERMOSTATS B 0411744 Standard Non adjustable 2 Defrost Thermostat CT 0411744 C Optional Adjustable Refrigeration Thermostat 3 LAMPS BALLASTS LED FIXTURES AND POWER SUPPLY D Bal...

Страница 2: ...nal legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection point B RH End of case to center of stub up area 36 1 4 921 60 1 4 1530 84 1 4 2140 132 3 8 3363 Back of case to center of stub up area 24 612 2...

Страница 3: ...4 F 14 F 4 F 17 F 7 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb C6X E 4 ft 1 6 6 ft 2 3 8 ft 3 2 12 ft 4 5 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound 3 of 9 P N 0485612_C HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM 31...

Страница 4: ...26 0 51 0 51 0 77 30 59 59 85 Additional 2 Row Canopy 0 51 1 02 1 02 1 54 59 118 118 170 Additional 3 Row Canopy 0 77 1 53 1 53 2 31 89 177 177 255 1 Row Rail Light 0 26 0 51 0 51 0 77 30 59 59 85 Optional Shelf Lighting T 8 Fluorescent 1 Row of Shelves 0 26 0 51 0 51 0 77 30 59 59 85 2 Rows of Shelves 0 51 1 02 1 02 1 54 59 118 118 170 3 Rows of Shelves 0 77 1 53 1 53 2 31 89 177 177 255 4 Rows o...

Страница 5: ... ft 0 91 m3 m ARI Total Display Area 3 Sq Ft Ft 4 92 ft2 ft 1 50 m2 m Shelf Area 4 Sq Ft Ft 11 73 ft2 ft 3 58 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated Volume less shelving and other unusable space Refrigerated Volume Unit of Length ft3 ft m3 m 3 Computed using ARI 1200 standard methodology Total Display Area ft2 m2 Unit o...

Страница 6: ...ctor 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 3 Row Canopy 5 4 5 5 Connector W B BL BL R BL R R R Optional Lighting 1 Row Rail B 4 ft 6 ft or 8 ft 12 ft 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have...

Страница 7: ...TRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Six Rows of Shelves 4 ft case Connector 4 5 5 5 B W Connector 6 ft or 8 ft case 12 ft case BL BL R BL BL BL W R W R B R 4 B BL BL BL R R R R 5 R BL 5 R BL BL R BL R 5 R BL BL 4 5 5 5 B W BL BL R ...

Страница 8: ... 7 7 R BL R BL R BL 7 7 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and LED Light Circuits for Two Rows of Shelves R R B Optional Shelf Lighting LED Fixtures...

Страница 9: ...BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND W Connector Optional Shelf Harness and LED Light Circuits for 3...

Отзывы: