E2SP  

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Engineering

Plan Views

Dimensions shown as inches and (mm).

10-2005

Ballast

Tray

Optional
Unrefrigerated
Rear Storage

12

(305)

Optional
Refrigerated
Rear Storage

16

(406)

8 Ft Case

28

 1

/

8

(714)

35

(889)

D

8

 3

/

(213)

Front

Waste Outlet

Water Seal

C

31

 1

/

4

(794)

47

(1194)

63

(1600)

B

E

E

A

Front to back dimensions do not include optional rear storage dimension.

4 ft

6 ft

8 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

48 

1

/

8

(1222)

72 

1

/

8

(1832)

96 

1

/

4

(2445)

144 

3

/

8

3667)

Maximum O/S dimension back to front 

(with bumper)

47  (1194)

47  (1194)

47  (1194)

47 (1194)

Back of case to front of front panel

35 (889)

35 (889)

35 (889)

35 (889)

Back of case to O/S edge of front skid rail

29 

3

/

(756)

29 

3

/

(756)

29 

3

/

(756)

29 

3

/

(756)

Width of skid rail

1

/

(114)

1

/

(114)

1

/

(114)

1

/

(114)

RH end of case to outside edge of external support

3

/

8

(35)

3

/

8

(35)

3

/

8

(35)

3

/

8

(35)

Distance between edges of 

external support and center support

NA

28 

1

/

(724)

40 

1

/

(1029)

40 

1

/

(1029)

Distance between edges of center supports

NA

NA

NA

44 (1118)

Distance between edges of external supports

37  (940)

NA

NA

NA

Stub-up area between front skid rail and front panel

3

/

4

(146)

3

/

4

(146)

3

/

(146)

3

/

4

(146)

Electrical Service                         

(Electrical Field Wiring connection point)

(B)

RH End of case to LH end of connection box

42 

1

/

8

(1070)

42 

1

/

8

(1070)

42 

1

/

8

(1070)

91 

3

/

8

(2321)

(E)

Back of storage to 

NONREFRIGERATED STORAGE

CONNECTION BOX

, center of knockout

7  (178)

7  (178)

7  (178)

7  (178)

(E)

Back of storage to 

REFRIGERATED STORAGE

CONNECTION BOX

, center of knockout

11  (279)

11  (279)

11  (279)

11  (279)

Waste Outlet

(C)

RH End of case to the center of waste outlet

24 

1

/

4

(616)

24 

1

/

4

(616)

24 

1

/

4

(616)

24 

1

/

4

(616)

(D)

LH End of case to the center of waste outlet

23 

7

/

8

(606)

47 

7

/

8  

(1216)

72 

3

/

(1848)

72 

1

/

(1832)

Back O/S of case to center of waste outlet

28 

1

/

(714)

28 

1

/

(714)

28 

1

/

(714)

28 

1

/

(714)

Water Seal

Edge of water seal to center of waste outlet

4  (102)

4  (102)

4  (102)

4 (102)

Outside diameter of the drip pipe

1

/

(38)

1

/

(38)

1

/

(38)

1

/

(38)

NOTE: Water seal outlet must clear front skid rail;
water seal rotation in forward direction only due to low base.

Refrigeration Outlet

Back of case to center of refrigeration outlet

31 

1

/

(794)

31 

1

/

(794)

31 

1

/

(794)

31 

1

/

(794)

RH end of case to center of refrigeration outlet

3

/

(213)

3

/

(213)

3

/

(213)

3

/

(213)

Содержание IMPACT Elite E2SP

Страница 1: ...d 2 Rear Storage C 0404551 Cavity Fan Ambient 3 D 0411744 Standard Non adjustable 4 Defrost Thermostat Item Part Description Wiring Item E 0353949 Optional Adjustable 5 Refrigeration Thermostat LAMPS AND BALLASTS F 0466234 Ballast Electronic 2 lamps 6 F 0466235 Ballast Electronic 3 lamps 6 F 0466236 Ballast Electronic 4 lamps 6 G Fluorescent Lamp 7 Replace with like fixtures SHOWN WITH OPTIONAL RE...

Страница 2: ...l Field Wiring connection point B Length of electrical raceway 36 1 8 918 26 5 8 676 36 1 8 918 36 1 8 918 RH End of case to center of farthest knockout 11 3 8 289 11 3 8 289 11 3 8 289 11 3 8 289 Back of case to center of end knockout 6 3 8 162 6 3 8 162 6 3 8 162 6 3 8 162 C RH End of case to RH end of raceway 6 1 8 156 6 1 8 156 6 1 8 156 6 1 8 156 Waste Outlet D RH End of case to the center of...

Страница 3: ...Deli Temp F 11 6 14 4 Indoor Unit Only Pressure Defrost Termination Temp F 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb E2SP 4 ft 0 9 6 ft 1 8 8 ft 1 9 12 ft 2 9 This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound Length Added ...

Страница 4: ...9 Distance between edges of center supports NA NA NA 44 1118 Distance between edges of external supports 37 940 NA NA NA Stub up area between front skid rail and front panel 5 3 4 146 5 3 4 146 5 3 4 146 5 3 4 146 Electrical Service Electrical Field Wiring connection point B RH End of case to LH end of connection box 42 1 8 1070 42 1 8 1070 42 1 8 1070 91 3 8 2321 E Back of storage to NONREFRIGERA...

Страница 5: ...HYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb E2SP 4 ft 0 9 6 ft 1 8 8 ft 1 9 12 ft 2 9 This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound Length Added to Lineup by Each End or Insulated Partition 1 in 5 of 10 P N 0453525B HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A C O I L Refrigeration ...

Страница 6: ...mbient Air Fan 0 26 0 26 0 26 0 26 23 23 23 23 Standard on Optional Refrigerated Rear Storage Cycling Anti sweat Heaters NA Minimum Circuit Ampacity With Standard Fans 120V 60Hz 0 90 1 60 1 60 2 30 With Rear Refrigerated Storage standard fans 1 96 3 46 3 46 5 56 With Energy Efficient Fans 120V 60 Hz 0 58 0 96 0 96 1 34 With Export Fans 230V 50Hz 0 58 0 96 0 96 1 34 Maximum Over Current Protection ...

Страница 7: ...Blue 4 1 2 or 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Optional Refrigerated Rear Storage 1 or 2 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 2 BROWN BAND 4 ft case has 1 Fan 6 ft case has 1 Fan 8 ft case has 2 Fans 12 ft case has 2 Fans 4 ft case has 1 Fan 6 ft case has 2 Fans 8 ft case has 2 Fans 12 ft case has 3 Fans Cavity Fan Ambient 120V NEUTRAL BROWN BAND 120V POWER Fan 3...

Страница 8: ...NING All components must have mechanical ground and the merchandiser must be grounded Connector 6 Connector G 7 7 7 Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G W R G G R R R G G G R BL BL Connector Connector B 4 ft 6 ft 8 ft 12 ft R R BL B...

Страница 9: ...G All components must have mechanical ground and the merchandiser must be grounded 120V POWER 120V NEUTRAL R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND 6 BL R R BL BL R 7 7 7 B 4 ft case has 1 Lamp 6 ft case has 2 Lamps 8 ft case has 2 Lamps 12 ft case has 3 Lamps 4 ft case has 1 ...

Страница 10: ...r stop extend beyond the load limit as shown in this illustration This configuration supports the air curtain and provides optimal case performance Check with Hussmann engineering before using a different configuration Load Limit 12 in 10 Recommended Angle Shelf Size 18 in 0 Impact Elite E2SP Meat Delicatessen Precut Packaged Produce 10 of 10 E2SP Data Sheet HUSSMANN CORPORATION Bridgeton MO 63044...

Отзывы: