2 of 10
E2SP
Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
E2SP
Meat, Delicatessen
Precut & Packaged
Produce
Standard
Configuration
(without Optional
Rear Storage)
Front to back dimensions do not include optional rear storage dimension.
4 ft
6 ft
8 ft
12 ft
General
(A)
Case Length
(without ends or partitions)
48
1
/
8
(1222)
72
1
/
8
(1832)
96
1
/
4
(2445)
144
3
/
8
(3667)
Maximum O/S dimension back to front
(with bumper)
47 (1194)
47 (1194)
47 (1194)
47 (1194)
Back of case to front of front panel
35 (889)
35 (889)
35 (889)
35 (889)
Back of case to O/S edge of front skid rail
29
3
/
4
(756)
29
3
/
4
(756)
29
3
/
4
(756)
29
3
/
4
(756)
Width of skid rail
4
1
/
2
(114)
4
1
/
2
(114)
4
1
/
2
(114)
4
1
/
2
(114)
RH end of case to outside edge of external support
1
3
/
8
(35)
1
3
/
8
(35)
1
3
/
8
(35)
1
3
/
8
(35)
Distance between edges of
external support and center support
NA
28
1
/
2
(724)
40
1
/
2
(1029)
40
1
/
2
(1029)
Distance between edges of center supports
NA
NA
NA
44 (1118)
Distance between edges of external supports
37 (940)
NA
NA
NA
Stub-up area between front skid rail and front panel
5
3
/
4
(146)
5
3
/
4
(146)
5
3
/
4
(146)
5
3
/
4
(146)
Electrical Service
(Electrical Field Wiring connection point)
(B)
Length of electrical raceway
36
1
/
8
(918)
26
5
/
8
(676)
36
1
/
8
(918)
36
1
/
8
(918)
RH End of case to center of farthest knockout
11
3
/
8
(289)
11
3
/
8
(289)
11
3
/
8
(289)
11
3
/
8
(289)
Back of case to center of end knockout
6
3
/
8
(162)
6
3
/
8
(162)
6
3
/
8
(162)
6
3
/
8
(162)
(C)
RH End of case to RH end of raceway
6
1
/
8
(156)
6
1
/
8
(156)
6
1
/
8
(156)
6
1
/
8
(156)
Waste Outlet
(D)
RH End of case to the center of waste outlet
24
1
/
4
(616)
24
1
/
4
(616)
24
1
/
2
(622)
72
1
/
4
(1835)
(E)
LH End of case to the center of waste outlet
23
7
/
8
(606)
47
7
/
8
(1216)
72
3
/
4
(1848)
72
1
/
8
(1832)
Back O/S of case to center of waste outlet
28
1
/
8
(714)
28
1
/
8
(714)
28
1
/
8
(714)
28
1
/
8
(714)
Water Seal
Edge of water seal to center of waste outlet
4 (102)
4 (102)
4 (102)
4 (102)
Outside diameter of the drip pipe
1
1
/
2
(38)
1
1
/
2
(38)
1
1
/
2
(38)
1
1
/
2
(38)
NOTE: Water seal outlet must clear front skid rail;
water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet
31
1
/
4
(794)
31
1
/
4
(794)
31
1
/
4
(794)
31
1
/
4
(794)
RH end of case to center of refrigeration outlet
8
3
/
8
(213)
8
3
/
8
(213)
8
3
/
8
(213)
8
3
/
8
(213)
Engineering
Plan Views
Dimensions shown as inches and (mm).
10-2005
A
12 Ft Case
28
1
/
8
(714)
31
1
/
4
(794)
35
(889)
E
8
3
/
8
(213)
Front
Waste Outlet
Water Seal
B
C
Electrical
6
3
/
8
(162)
D
47