background image

Elite 

Medium Temperature

P/N 0453523

1-1

HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483  U.S.A.

NSF CERTIFICATION

These merchandisers are manufactured to meet
ANSI / National Sanitation Foundation (NSF

®

)

Standard #7 requirements. Proper installation is
required to maintain certification. Near the serial
plate, each case carries a label identifying the type
of application for which the case was certified.

ANSI

/

NSF-7 Type I – Display Refrigerator / Freezer

Intended for 75°F / 55%RH Ambient Application

ANSI

/

NSF-7 Type II – Display Refrigerator / Freezer

Intended for 80°F / 55%RH Ambient Application

ANSI

/

NSF-7 – Display Refrigerator 

Intended for Bulk Produce

LOCATION

These merchandisers are designed for displaying
products in air conditioned stores where tempera-
ture is maintained at or below the ANSI / NSF-7
specified level and relative humidity is maintained
at or below 55%. 

Placing refrigerated merchandisers in direct sun-
light, near hot tables or near other heat sources
could impair their efficiency.

Like other merchandisers, these are sensitive to
air disturbances. Air currents passing around
merchandisers will seriously impair their opera-
tion. Do NOT allow air conditioning, electric
fans, open doors or windows, etc. to create air
currents around the merchandisers.

Product should always be maintained at proper
temperature. This means that from the time the
product is received, through storage, preparation
and display, the temperature of the product must
be controlled to maximize the life of the product.

The exterior frames on these cases provide space
for air circulation. However, in high ambient 
conditions, sweating may still occur. If this 
happens install a method of forced ventilation
such as a fan ventilation kit.

SHIPPING DAMAGE

All equipment should be thoroughly examined for
shipping damage before and during unloading.

This equipment has been carefully inspected at
our factory. Any claim for loss or damage must be
made to the carrier. The carrier will provide any
necessary inspection reports and/or claim forms.

Apparent Loss Or Damage

If there is an obvious loss or damage, it must be
noted on the freight bill or express receipt and
signed by the carrier’s agent; otherwise, carrier
may refuse claim. 

Concealed Loss Or Damage

When loss or damage is not apparent until after
equipment is uncrated, retain all packing materials
and submit a written request to the carrier for
inspection, within 15 days.

EXTERIOR LOADING

Do NOT walk on top of merchandisers

or

damage to the merchandisers and serious 
personal injury could occur. T

HEY ARE NOT

STRUCTURALLY DESIGNED TO SUPPORT EXTERNAL

LOADING

such as the weight of a person. Do not

place heavy objects on the case.

INSTALLATION

Do not walk or put heavy objects on case.

CAUTION

!

Содержание IMPACT Elite E1

Страница 1: ...t Delicatessen Dairy and Produce Merchandisers Installation Operation Manual Shipped With Case Data Sheets P N 0453523 Impact Elite Series December 2005 I IM MP PO OR RT TA AN NT T Keep in store for f...

Страница 2: ...1 Installing Drip Piping 3 1 Installing Lower Front Panels 3 2 START UP OPERATION Start up 4 1 Load Limits 4 1 Stocking 4 1 Multi deck Shelf Alignment 4 2 Multi deck Shelf Configuration 4 2 Installing...

Страница 3: ...ct should always be maintained at proper temperature This means that from the time the product is received through storage preparation and display the temperature of the product must be controlled to...

Страница 4: ...r drainage of defrost water When leveling merchandisers use a carpenter s level as shown Leveling shims are provided with each merchandiser for use if needed The shims are big enough so that you can l...

Страница 5: ...helf supports and front air grilles from the right end 3 Remove the rear panel s from the right end On multi deck cases remove the lower back panel first To remove a panel lift it up from its bottom e...

Страница 6: ...iser into position against the first Match the alignment rod and pin with the corresponding holes 2 Fasten fronts together using cap screws flat washers lock washers and nuts Tighten only until front...

Страница 7: ...lexiglass pieces enough to apply a bead of 40 cement down one edge inside of seam 3 Apply cement with applicator to one or both surfaces Join immediately 4 Realign front plexiglass and push together t...

Страница 8: ...w for a precise right angle cut 5 Lubricate the inside of the vinyl with soapy water or silicone spray 6 Starting at the left end of the line up butt end of the vinyl bumper against end cap While appl...

Страница 9: ...REFRIGERATION SYSTEM BRANCH as this may result in poor refrigeration control and compressor failure Interconnecting piping inside the merchandiser must be located as shown below to allow room for lift...

Страница 10: ...third of case run load and again after the second third Do not reduce below the case suction line size Case suction lines should enter at the top of the branch line LIQUID LINE May be reduced by one...

Страница 11: ...st cycles for proper operation Refer to the data sheets for application data The Time Clock initiates defrost The evaporator fans continue to circulate air across the evapora tor coil melting any fros...

Страница 12: ...circuit the defrost termination thermostats are wired in series ALWAYS CHECK THE SERIAL PLATE FOR COMPONENT AMPERES IDENTIFICATION OF WIRING Leads for all electrical circuits are identified by colore...

Страница 13: ...ing the water seal must be used as part of the drip piping to prevent air leakage or insect entrance Never use two water seals in series in any one drip pipe DOUBLE WATER SEALS IN SERIES WILL CAUSE AN...

Страница 14: ...nyl cove base trim field supplied The size of trim needed will depend on how much the floor is out of level To install the trim to the front panel 1 Remove all dirt wax and grease from the area of the...

Страница 15: ...h merchandiser has a load limit decal Shelf life of perishables will be short if load limit is violated AT NO TIME SHOULD MERCHANDISERS BE STOCKED BEYOND THE LOAD LIMITS INDICAT ED DO NOT BLOCK HONEYC...

Страница 16: ...be adjusted to accommodate shallow or volume displays bulky items such as hams or chickens The upper shelves are individually mounted in 1 in 25 mm increments and have two position brack ets permitti...

Страница 17: ...llustration below It is typical of D5 C5 and D6 models Note that other models will have fewer rows of shelves Starting from the left hand bottom section choose the location for the first shelf X 1 Sec...

Страница 18: ...upport set the next shelf X 4 in the desired location Remove the cap and insert the shelf plug Continue working left to right installing shelves X 5 and X 6 Note Since the location for the remaining s...

Страница 19: ...ons in Multi deck Merchandisers Return Air Grille Shelf Price Tag Molding Suggested Mounting Locations in Single Deck Glass Front Impact Merchandisers Acrylic Package Guard Facing Out Double Stick Tap...

Страница 20: ...warmest part of a mechan ically refrigerated unit and in the coolest part of a hot FOOD storage unit B Except as specified in C of this section cold or hot holding EQUIPMENT used for POTENTIALLY HAZA...

Страница 21: ...interior surfaces A hose on rail lights canopy lights or any other electrical connection Do Remove the product and all loose debris to avoid clogging the waste outlet Store product in a refrigerated...

Страница 22: ...OR BACK PANELS The interior back panels may be removed for cleaning and to gain access to the evaporator coils Remove the rear interior back panels as follows 1 DISCONNECT THE ELECTRICAL POWER TO THE...

Страница 23: ...chandiser CLEANING BUMPERS Clean bumpers with household spray cleaner To remove marks from a ballpoint pen use hair spray or dry erase cleaner CLEANING PREP TOP Prep areas and bins must be kept clean...

Страница 24: ...holding bottom of motor to fan basket 6 Replace fan motor and blade 7 Lower fan plenum 8 Reconnect fan to wiring harness 9 Turn on power 10 Verify that motor is working and blade is turning in the cor...

Страница 25: ...switch is located on the rail REPLACING LAMP HOLDERS AND END CAPS The Impact lamp holder is designed to snap into the sheet metal of the case The lamp holder has a locking nub which fits inside the g...

Страница 26: ...st are located at the top of the merchandiser inside the canopy The switch in the canopy operates both the canopy and the shelf lamps The rail lamp has a separate switch 1 DISCONNECT POWER TO THE MERC...

Страница 27: ...1 DISCONNECT THE ELECTRICAL POWER TO THE MERCHANDISER 2 Remove screws that secure the access panel then remove the panel 3 Remove screws attaching the raceway cover then remove cover 4 Service or repl...

Страница 28: ...r 2 Apply an ABS and PVC compatible primer sealer to outside of PVC coupling and inside of drain Insert coupling into drain fitting 3 Install a PVC adapter on the drip trap Apply primer sealer to a st...

Страница 29: ...062 Phone 1 800 527 9916 NOTE Hussmann Aluminum melts at 1125 F 607 C Aladdin 3 in 1 rod at 732 F 389 C X Ergon Acid core at 455 F 235 C Technique 1 Locate Leak 2 REMOVE ALL PRESSURE 3 Brush area UNDE...

Страница 30: ...y information or other support contact your Hussmann representative Please include the model and serial number of the product Hussmann Corporation Corporate Headquarters Bridgeton Missouri U S A 63044...